HP StorageWorks P9000 Manual page 197

Remote web console messages
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

Table 53 Error codes (part code 6505) (continued)
Part
Error
Error Message
Code
Number
6505
58510
The Add Pair (Paircreate) operation
failed.
The combination of the specified primary
data volume number (LDKC:CU:LDEV)
and the mirror ID is the same as the
combination specified from another
primary subsystem.
Please check the mirror ID assigned to
the specified primary data volume
number (LDKC:CU:LDEV) from the
secondary subsystem.
In the current microcode version, please
specify a mirror ID different from the ID
used by an existing pair, when you
create a pair by using the same primary
data volume number (LDKC:CU:LDEV).
6505
58530
The capacity of the specified volume is
too small.
6505
58531
A journal volume cannot be added
because the combination of the
emulation types for the journal volumes
is not correct.
6505
58532
The Add Pair (Paircreate) operation
failed, because the emulation type is
different between the master journal and
the restore journal.
6505
58550
The operation to add journal volumes
failed due to the mirror status of the
specified journal.
6505
58552
The operation failed because the license
of the Mainframe Array Management
was not installed in the remote
subsystem.
6505
58553
The specified volume cannot be used as
a journal volume because it is used by
Parallel Access Volumes.
6505
58560
A journal volume cannot be added
because the capacity of shared memory
is insufficient.
6505
58561
The Add Pair operation or the Resume
Pair operation failed, because the timer
type of the master journal was different
from the one of restore journal.
6505
58562
The specified volumes or the volumes in
the specified journal were deleted.
However, the blockade of the volumes
failed.
Record the volumes that could not be
blocked.
And, clear the Preview list.
Then please contact HP Technical
Support to block the volumes.
Recommended Action
Check the mirror ID assigned to the
specified primary data volume number
(LDKC:CU:LDEV) from the secondary
storage system, and assign a mirror ID
that is not used, and retry the operation.
Check the capacity of the volume, and
specify a volume with larger capacity.
Check the emulation types of the
specified volumes.
Check the emulation type of the master
and the restore journal.
Check the mirror status of the specified
journal.
Install Mainframe Array Management in
the remote storage system or change the
access attribute of the specified primary
data volume to Read/Write.
Check whether the specified volume is
used by Parallel Access Volumes.
Please contact HP Technical Support to
install additional shared memory.
Check the timer type of the master and
the restore journal.
Record the volumes that could not be
blocked.
Clear the Preview list.
Please contact HP Technical Support to
block the volumes.
Severity
Level
W
W
W
W
W
W
W
E
W
W
Part code 6505 197

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xp p9500Storageworks p9500

Table of Contents