Table 53 Error codes (part code 6505) (continued)
Part
Error
Code
Number
6505
58490
6505
58500
6505
58501
6505
58502
6505
58503
6505
58504
6505
58508
196 Message (part code group 6nnn)
Error Message
Only the pair option of the primary data
volume was updated. Failed to update
the pair option of the secondary data
volume.
The Add Pair (Paircreate) operation
failed because the Continuous Access
Journal or the Continuous Access Journal
Z function of the secondary storage
system does not support external
volumes.
The Paircreate operation failed because
the Continuous Access Journal function
of the secondary storage system does
not support Data Retention VMA.
The operation failed because the
capacity of the secondary storage system
has exceeded the licensed capacity of
Open System Array Management.
The specified operation failed due to the
attribute or the mirror status in the
journal.
The operation failed. Please refresh the
window and retry the operation. If this
problem persists, please contact HP
Technical Support.
The Add Pair (Paircreate) operation
failed because the IO suppression mode
of the specified primary data volume was
enabled.
Recommended Action
A communication error between the
primary and the secondary storage
systems occurred, or the microcode of
the secondary storage system does not
support the change pair option function.
Check the main microcode of the
secondary storage system, and contact
HP Technical Support to confirm whether
the microcode supports the change pair
option function. If the microcode supports
the function, contact HP Technical
Support because a communication error
might have occurred.
Check the DKCMAIN microcode version
of the secondary storage system, and
contact HP Technical Support to confirm
whether the Continuous Access Journal
or the Continuous Access Journal Z
function supports external volumes.
Check the DKCMAIN microcode version
of the secondary storage system, and
contact HP Technical Support to confirm
whether the Continuous Access Journal
function supports Data Retention VMA.
Confirm the licensed capacity of the
Open System Array Management of the
secondary storage system. To perform
the specified operation, purchase a
license key that allows you to use a
capacity larger than the current capacity.
Check the attribute and the mirror status
of the journal.
If this problem persists, please contact
HP Technical Support.
Disable the IO suppression mode of the
specified primary data volume on the
Universal Volume Mgr window.
Severity
Level
E
W
W
W
W
W
W