Table 53 Error codes (part code 6505) (continued)
Part
Error
Error Message
Code
Number
6505
8788
The specified volume is not defined in
the secondary storage system.
6505
8791
The specified primary data volume is
online from hosts.
6505
8795
The operation failed because the
specified primary data volume was used
by Business Copy or Business Copy Z
and satisfied one of the following
conditions:
The volume was a Business Copy
S-VOL in non-PSUS status.
The volume was a Business Copy Z
T-VOL in non-Split status.
The volume was a reserved volume.
The volume was in the Reverse Copy
status.
6505
8796
The operation failed because the
specified secondary data volume was
one of the following:
An S-VOL or reserved volume of
Business Copy
A T-VOL or reserved volume of
Business Copy Z.
A T-VOL of Compatible FlashCopy.
A Business Copy volume in the
Reverse Copy status
A Business Copy Z volume in the
Reverse Copy status
6505
8819
The specified secondary data volume
must not be:
in an intervention-requested condition
in a protected condition
in an unusable condition
a Business Copy S-VOL or a Business
Copy Z T-VOL
a volume reserved by Business Copy
or Business Copy Z
a volume used by Auto LUN
a Business Copy P-VOL in Swap or
Reverse Copy status
a Business Copy Z S-VOL in Swap or
Reverse Copy status
6505
8822
An I/O error occurred on the secondary
data volume.
6505
8830
The specified primary data volume is
already reserved by Auto LUN.
Recommended Action
Check the port, GID, and LUN settings
in the secondary storage system.
Vary the path offline from the other host,
then retry the operation.
Check the status of the primary data
volume from the host or the SVP.
Check the status of the secondary data
volume from the host or the SVP.
Check the status of the secondary data
volume.
Check the SSB log, then contact HP
Technical Support.
Volumes reserved by Auto LUN cannot
be specified as primary data volumes.
Check the status of the specified primary
data volume from the host or the SVP.
Severity
Level
W
W
W
W
W
E
W
Part code 6505