Option
Description
-d[g]
Searches a group on the configuration definition file (local instance) for the specified raw_device,
<raw_device>
and if the specified raw_device is contained in the group, the target volume is executed as the paired
[MU#]
logical volume (-d) or group (-dg). This option is effective without specification of "-g <group>" option.
If the specified the raw_device is contained in two or more groups, the command is executed on the
first group.
-d[g] <seq#>
Searches a group on the configuration definition file (local instance) for the specified LDEV, and if
<LDEV#> [MU#]
the specified LDEV is in the group, the target volume is executed as the paired logical volume (-d) or
group (-dg). This option is effective without specification of "-g <group>" option. If the specified LDEV
is contained in two or more groups, the command is executed on the first group. The <seq #> <LDEV
#> values can be specified in hexadecimal (by addition of "0x ") or decimal notation.
-fx
Displays the LDEV/STLBA/ENLBA number in hexadecimal.
-fd
Displays the relation between the Device_File and the paired Volumes, based on the Group (as
defined in the local instance configuration definition file). If Device_File column shows "Unknown"
to HOST (instance), then the volume is not recognized on own HOST, and raidvchkdsp command
is rejected in protection mode. Non-permitted volume is shown without LDEV# information (LDEV#
is "– ").
-fe
Displays the serial# and LDEV# of the external LUNs mapped to the LDEV for the target volume by
adding to last column (ignores the format of 80 column).