Configuration Setting Commands; Raidcom; Syntax; Options And Parameters - HP StorageWorks P9000 Reference Manual

Raid manager reference guide
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

5 Configuration setting commands

This chapter describes the configuration setting commands.

raidcom

The configuration change is instructed.
Executes by specifying respective parameters and values that are expressed in
copy_grp" (page 128)

Syntax

Displaying Help
raidcom { [-h]
Log-in and Log-out
raidcom {-login [<user_name> <password>] | -logout] [-s <seq# > | -u <unit#>]
Instruction of Configuration change (Line by Line mode)
raidcom <action> <object> [<param> <value> ] [-fx] [-checkmode <check mode>] [-store <filename>] [-nomsg]
[-login [<user_name> <password>] | -logout] [-s <seq# > | -u <unit#>]
Instruction of Configuration change (Transaction mode)
raidcom -zt <filename> [-load <work_filename>] [-checkmode <check mode>]

Options and parameters

Option
[-h ]
[-login [<user_name>
<password>]]
[-logout]
[-s <Seq#>]
[-u <Unit#>]
<action> <object>
[<param> <value>...]
[-fx]
[ -checkmode < check
mode> ]
[ -store <file name> ]
126 Configuration setting commands
and later.
Description
Displays raidcom help .
Specifies user authentication for the DKC. Specifies user name and password.
If no user authentication is done yet and the -login option is omitted, the input of the user name
and the password is required. And, in case of omitting the user name and the password by
specifying -login option, the input of the user name and the password is required.
The maximum number of the user who can log in at same time is 512.
This option deletes the cache of the session control table in the DKC and logs out from the DKC
(command device). Also deletes all the authentication files corresponding to the DKC.
At the time of next login, the RAID Manager command requires the user name and the password.
If the same user is set for multiple hosts, the session control table of each host is managed so
that the logout will be applied only to the relevant host.
This option specifies the serial number.
This option specifies the unit ID of command device as HORCM_CMD of configuration file.
This option specifies each command name that is expressed in
(page 128)
and the parameters and values that are required for each operation.
This option displays the LDEV number in hexadecimal notation.
This option specifies when executing Precheck function (execute checking commands only). it
specifies the following value.
Precheck: When this option is specified, the actual process is not executed for DKC even if the
command is executed.
This option is available to specify the setting of $HORCC_NO_EXEC environment variable
and $HORCC_CTX_CHK environment variable.
This option specifies a file name of a configuration file to be created for implementation check.
"raidcom add
"raidcom add copy_grp"

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xp p9500Storageworks p9500

Table of Contents