Error Codes; Examples - HP StorageWorks P9000 Reference Manual

Raid manager reference guide
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

Error codes

Unrecoverable errors are fixed and not resolved, even after re-executing the command. If the
command failed, the detailed status will be logged in the RAID Manager command log
($HORCC_LOG), even if the user script has no error handling.
Category
Volume status
Unrecoverable

Examples

Examples of the pairsyncwait command with and without the -nowait option follow.
pairsyncwait command examples
# pairsyncwait -g oradb
UnitID
CTGID
0
3
# pairsyncwait -g oradb
UnitID
CTGID
0
3
# pairsyncwait -g oradb
UnitID
CTGID
0
3
# pairsyncwait -g oradb
UnitID
CTGID
0
3
# pairsyncwait -g oradb
UnitID
CTGID
0
3
# pairsyncwait -g oradb
UnitID
CTGID
0
3
ã Q-Marker (01003408ef) is invalid when P-VOL was resynchronized while this command is executed.
The output of the pairsyncwait command is:
UnitID: Unit ID in the case of multiple storage system connection.
CTGID: CTGID within Unit ID.
Q-Marker: The latest sequence # of MCU PVol (Marker) when the command is received.
Status: The status after the execution of command.
Q-Num: The number of process queue to wait for synchronization within the CTGID.
QM-Cnt: The number of remaining Q-Markers within CT group of the Unit. HORCAsync/Cnt Ac-J
sends a token called "dummy recordset" at regular intervals, therefore QM-Cnt always shows "2"
or "3" even if Host has NO writing.
Following is an arithmetic expression for determining the remaining Data in a CT group:
Remaining data in CT group = Sidefile capacity * Sidefile percentage / 100
Sidefile percentage is the rate showed to "%" column with "PAIR" state by Pairdisplay command.
Sidefile capacity is the capacity within 30% to 70% of the cache setting as the sidefile.
Following is an arithmetic expression for determining the average data per Q-Marker in a CT
group:
Data per Q-Marker = Remaining data in CT group / QM-Cnt
Error Code
Error Message
EX_INVVOL
Invalid volume status
-nowait
<=-nowait is specified.
Q-Marker
Status
Q-Num
01003408ef
NOWAIT
-t 100
<=-nowait is not specified.
Q-Marker
Status
Q-Num
01003408ef
DONE
-t 1
Q-Marker
Status
Q-Num
01003408ef
TIMEOUT
-t 100 -m 01003408ef
Q-Marker
Status
Q-Num
01003408ef
DONE
-t 100
Q-Marker
Status
Q-Num
01003408ef
BROKEN
-t 100
-m
01003408ef
Q-Marker
Status
Q-Num
01003408ef
CHANGED
Recommended Action
Confirm pair status using pairdisplay -l.
2
2
3
0
0
0
Value
222