HP StorageWorks P9000 Reference Manual page 103

Raid manager reference guide
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

Option
Description
-I [H] [M]
Specifies the command as [HORC]/[HOMRCF] or [Continuous Access Synchronous]/[Business
[instance#]
Copy], and used when specifying the RAID Manager instance number.
or
-I [TC] [SI]
[instance#]
-g <group>
Specifies a group name defined in the configuration definition file. The command is executed for
the specified group unless the -d <pair Vol> option is specified.
-d <pair Vol>
Specifies paired logical volume name defined in the configuration definition file. When this option
is specified, the command is executed for the specified paired logical volume.
-d[g]
Searches a group on the configuration definition file (local instance) for the specified raw_device.
<raw_device>
If the specified raw_device is found, the command is executed on the paired logical volume (-d) or
[MU#]
group (-dg). This option is effective without specification of "-g <group>" option. If the specified the
raw_device is contained in two or more groups, the command is executed on the first group.
-d[g] <seq#>
Searches a group on the configuration definition file (local instance) for the specified LDEV, and if
<LDEV#> [MU#]
the specified LDEV is contained in the group, the command is executed on the paired logical volume
(-d) or group (-dg). This option is effective without specification of "-g <group>" option. If the specified
LDEV is contained in two or more groups, the command is executed on the first group. The <seq
#> <LDEV #> values can be specified in hexadecimal (by addition of "0x ") or decimal.
-m <marker>
Specifies the sequence # of MCU P-VOL, called the Q-marker. If the application gets Q-marker as
the result of execution of pairsyncwait because of timeout or "-nowait", the application can reconfirm
the completion of Async transfer by using pairsysncwait with Q-marker. If the application does not
specify Q-marker, RAID Manager uses the latest sequence # when RAID Manager receives
pairsysncwait. It is also possible to wait for the completion from S-VOL side with this option.
Q-Marker format: = iissssssss, where ii = incarnation # of pair volume, and ssssssss = P-VOL serial
#.
-t <timeout>
Specifies the timeout value to wait for the completion of RCU DFW area. The unit is 100 ms. MCU
gets the latest sequence # from RCU at regular interval.
-nowait
Gets the latest sequence # of MCU PVol and CTGID without waiting. When this option is specified,
the latest sequence # of MCU PVol is reported immediately, and -t <timeout>option is ignored.
-nomsg
Suppresses messages to be displayed when this command is executed from a user program. This
option must be specified at the beginning of the command arguments.
pairsyncwait 103