Chapter 6
3. Click the Consistency Check button in the Logical Drive Information
dialog box. See Figure 6-3.
Figure 6-3. Logical Drive Information Dialog Box
A message is displayed asking if you would like consistency restored in the
event of errors. See Figure 6-4.
4. Click No if you just want to carry out the consistency check.
There is no risk of data loss if No is selected. Errors will still be reported to
the Error Table, but no attempt will be made to correct them.
CAUTION
To prevent corrupting real data, use the Yes option with
caution. If consistency data is badly corrupted on a logical
drive, attempting to restore consistency may result in
corrupting real data.
5. Click Yes to restore consistency during the process.
Maintenance Processes
129