Chapter 6
Four PCI slots (P7-P10) support full-length 32 or 64-bit boards at clock
rates of 66 or 33 MHz. These slots only support boards with +3.3 VDC
power and Universal boards. These slots have keys in the lower half of the
board slot to prevent boards without +3.3 volt power from being inserted
into the slots.
The default bus speeds for slots 7-10 can be changed to 66 MHz in the
Setup Utility. However, if a 33 MHz PCI adapter board is inserted into the
bus, then the bus speed (at boot time) will be downgraded to 33 MHz.
NOTE
The HP NetServer has 4 Bus controllers handling four busses,
0, 1, 2, and 3 (default). If a DAC board or a similar type
controller is installed, additional buses are automatically
reassigned, up to 6 busses.
Shaded rectangle
represents the
depressed side
of the configuration
switch
Figure 6-2. I/O Baseboard Configuration Switch
CAUTION
To prevent a system crash or hang, do not close the PCI Hot
Plug disable switch. If the PCI Hot Plug disable switch is
closed, all Hot Plug capability for all PCI slots is lost and the
HP NetServer must be shutdown to remove or replace boards.

Installing Accessory Boards

Use this procedure to install all PCI accessory boards for the following situations:
The initial installation of PCI Hot Plug boards
Installing Additional Boards
1
Reserved
2
Recovery Boot
3
Reserved
4
Reserved
5
CMOS Clear
6
Password Clear
7
PCI Hot-Swap Switch Disable
8
Reserved
Closed = On
Open = Off
Front of HP NetServer
65