Chapter 8
Extend rack's
anti-tip foot
from front of rack
for saftey.
Figure 8-5. Mounting the Slides to the Rack Columns
3. With the slide pushed firmly into position, insert two screws through the
slide's front bracket into the rack nuts on the left-front column.
a. Secure the screws only loosely at first, so the bracket can settle into the
lowest possible position.
b. Then tighten the screws until the bracket is held firmly to the column.
4. Fasten the slide's rear bracket to the rack nuts on the left-rear column.
a. Secure the screws only loosely at first, so the bracket can settle into the
lowest possible position.
b. Then tighten the screws until the bracket is held firmly to the column.
5. Attach the other slide to the right-front and right-rear rack columns.
Repeat Steps 2-4.
Rack Mounting the HP NetServer
95