Table 6-9
Screen message
914— Hood Lock Coil is not
Connected
916—Power Button Not
Connected
917—Front Audio Not
Connected
918—Front USB Not
Connected
919—Multi-Bay Riser Not
Connected
920—Fatal error on QPI link X
921—Fatal error on QPI
Protocol link X
922—Fatal error on PCIe slot
X
923—Fatal error on ESI port 0
924—Fatal error on IOH core
X
925—Fatal error on IOH
miscellaneous
926—Fatal error on IOH Vtd
927—Fatal error on DIMM in
slot CPU X DIMM Y
928—Fatal machine check
detected on CPU X
144
Chapter 6 Diagnostics and troubleshooting
POST error messages (continued)
Probable cause
Mechanism is missing or is not
connected.
Power button cable is disconnected
from the system board.
Front Audio mechanism is missing or is
not connected.
Front USB mechanism is missing or is
not connected.
Multi-Bay riser mechanism is missing
or is not connected.
Fatal error detected on QPI link x,
where x is 0 or 1. This type of error is
identified on the line following the
error message.
Fatal error detected in QPI link x
protocol, where x is 0 or 1. This type
of error is identified on the line
following the error message.
Fatal error occurred in the designated
slot.
A fatal error occurred on ESI port 0.
slot.
Fatal error detected on IOH core x,
where x is 0 or 1. This type of error is
identified on the line following.
Fatal miscellaneous error detected on
IOH core x, where x is 0 or 1.
Fatal error detected in the Intel
Virtualization Technology.
Fatal multibit ECC error detected on
the DIMM in the slot labeled DIMM x
(where x is 1 - 4), as labeled on the
system board.
Recommended action
1.
Reconnect or replace the missing mechanism.
2.
Reseat or replace the missing mechanism cable.
Reconnect the cable and restart.
1.
Replace or reconnect the missing front audio
mechanism to the system board.
2.
Reseat or replace the missing mechanism cable.
1.
Replace or reconnect the missing Front USB
mechanism to the system board.
2.
Reseat or replace the missing mechanism cable.
1.
Replace or reconnect the missing Multi-Bay
mechanism to the system board.
2.
Reseat or replace the missing mechanism cable.
Potential system board problem; contact HP Support.
Potential system board problem; contact HP Support.
Move the card to a different slot. If the problem
persists, replace the card.
Verify that the ESI port device is connected and
working properly.
Potential system board problem; contact HP Support.
Potential system board problem; contact HP Support.
Potential system board problem; contact HP Support.
Replace the DIMM in the identified slot.
Contact HP support.