Saving and printing information in HP Vision Field Diagnostics

You can save the information displayed in the HP Vision Field Diagnostics Survey, History and Errors
tabs to a diskette or a USB flash drive. You can not save to the hard drive. The system will automatically
create an html file that has the same appearance as the information displayed on the screen.
1.
Insert a diskette or USB flash drive if running HP Vision Field Diagnostics from CD.
2.
Click Save in the bottom on any of the Survey, History or Errors tabs. All three log files will be saved
regardless of from which tab the Save button was clicked.
3.
Select the drive onto which you will save the log files and click the Save button. Three html files
will be saved to the inserted diskette or USB flash drive.
NOTE:
files have been written to the media.
4.
Print the desired information from the storage device used to save it.
NOTE:
the screen. Be sure to remove the USB flash drive or CD from the optical drive.

POST error messages

Power On Self Test (POST) is a program run at startup that initializes and runs tests on installed
hardware. An audible and/or visual message appears if the POST encounters a problem. POST checks
the following items to ensure that the workstation system is functioning properly:
NOTE:
If the power-on password is set, a key icon appears on the screen while POST is running. You
must enter the password before continuing.
Table 6-18
Screen message
101—Option ROM Error
102—System Board Failure
103—System Board Failure
110—Out of Memory for
Option ROMs
140 Chapter 6 System diagnostics and troubleshooting
Do not remove the diskette or USB key until you see a message indicating that the html
To exit HP Vision Field Diagnostics, click the Exit Diagnostics button at the bottom of
POST error messages
Probable cause
System ROM checksum
DMA, timers, and so on
DMA, timers, and so on
Option ROM for a device was unable
to run due to memory constraints.
Recommended action
Verify the correct ROM:
1.
Flash the ROM, if needed.
2.
If an expansion card was recently added, remove
it to find out if the problem remains.
3.
Clear CMOS. If the message disappears, there
might be a problem with the expansion card
4.
Replace the system board.
1.
Clear CMOS.
2.
Remove expansion boards.
3.
Replace the system board.
1.
Clear CMOS.
2.
Remove expansion boards.
3.
Replace the system board.
Run the Computer Setup (F10) Utility to enable the
ACPO/USB Buffers at Top of Memory under the
Advanced>Power-On option.