Epson SureLab D3000 - Double Roll Administrator's Manual page 41

Document
Hide thumbs Also See for SureLab D3000 - Double Roll:
Table of Contents

Advertisement

Correction chart color measurement (for the
"i1iSis")
A
Check that the color measurement device you
want to use is connected.
Tip:
For more information on color measurement
device, see the document supplied with the
device.
B
Click Measure Color from Correction Value
Creation Phase.
C
When the screen is displayed, check that the
light on the right of the color measurement
device is flashing green, and then insert the
correction chart that matches the color chart ID
and preset ID displayed on the screen into the
color measurement device.
Color measurement starts.
Settings/Maintenance
Tip:
O The color chart ID and preset ID are printed
O If the paper width of the correction chart is
D
When color measurement is complete, click
OK.
Continue to create the correction value.
U "Create, verify, and write the correction value" on
page 43
42
at the bottom of the correction chart.
wider than the maximum supported width
of the color measurement device, cut off the
margin along the cutoff line on the chart.