Cisco MDS 9124 - Fabric Switch Reference page 96

Cisco mds 9000 family command reference - cisco mds san-os release 3.0(1) through 3.3(1a) (ol-16217-01, april 2008)
Hide thumbs Also See for Cisco MDS 9124 - Fabric Switch:
Table of Contents

Advertisement

Searching and Filtering CLI Output
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
fc4/6
fc4/7
fc4/8
fc4/9
fc4/10
fc4/11
fc4/12
fc4/13
fc4/14
fc4/15
--More--
The following is partial sample output of the show running-config | exclude EXEC command. It
excludes any output line that contain the pattern
switch# show running-config | exclude vsan
version 2.1(1a)
poweroff module 9
fcdomain fcid database
ssm enable feature nasb interface fc4/1-4
ssm enable feature santap module 4
ssm enable feature nasb interface fc9/1-4
ssm enable feature santap interface fc9/5-8
ssm enable feature santap interface fc9/21-28
switchname switch
boot kickstart bootflash:/b2193 sup-1
boot system bootflash:/r2193 sup-1
boot kickstart bootflash:/b2193 sup-2
boot system bootflash:/r2193 sup-2
boot ssi bootflash:/laslc1.bin module 1
boot ssi bootflash:/laslc1.bin module 2
boot ssi bootflash:/laslc1.bin module 3
boot ssi bootflash:/laslc1.bin module 4
boot ssi bootflash:/laslc1.bin module 7
boot ssi bootflash:/laslc1.bin module 8
boot ssi bootflash:/laslc1.bin module 9
line console
speed 38400
--More--
The following is partial sample output of the show interface EXEC command. It includes all output with
the pattern
switch# show interface | include vsan
[information deleted]
The following is partial sample output of the show interface EXEC command. It includes all output with
the pattern
switch# show interface | include FX next 5 prev 5
fc4/1 is down (SFP not present)
Cisco MDS 9000 Family Command Reference
1-22
1
FX
--
1
FX
--
1
FX
--
1
E
on
1
FX
--
1
FX
--
1
FX
--
1
FX
--
1
FX
--
1
FX
--
.
vsan
Port vsan is 1
Port vsan is 1
Port vsan is 1
Port vsan is 1
Port vsan is 1
Port vsan is 1
plus the next and previous five lines of output.
FX
Hardware is Fibre Channel
Port WWN is 20:c1:00:05:30:00:06:de
Admin port mode is FX
Port vsan is 1
Receive data field Size is 2112
Beacon is turned off
5 minutes input rate 0 bits/sec, 0 bytes/sec, 0 frames/sec
sfpAbsent
--
sfpAbsent
--
sfpAbsent
--
notConnected
swl
sfpAbsent
--
sfpAbsent
--
sfpAbsent
--
sfpAbsent
--
sfpAbsent
--
sfpAbsent
--
.
vsan
Chapter 1
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
OL-16217-01, Cisco MDS SAN-OS Release 3.x
CLI Overview

Advertisement

Table of Contents
loading

Table of Contents