control commands—that are automatically added before or after the print job. You
can define up to eight named strings, and you can set up each queue so that any of
these named strings precedes the print data ("prepend string name") or follows the
print data ("append string name").
Name of the user-defined queue. This name can be up to 32 characters
Queue
long, and can consist of any displayable ASCII characters. You can
Name
define up to six user-defined queues.
Name of the string to be added before the print data ("prepended").
Prepend
String
Type in a string name chosen from the table defined at the bottom of
Name
the window.
Name of the string to be added after the print data ("appended"). Type
Append
String
in a string name chosen from the table defined at the bottom of the
Name
window.
Processing instruction for the queue:
RAW
a raw queue as a print job that has already been formatted in
PCL, PostScript, or HP-GL/2, and sends it to the printer without
modification. (Note that any user-defined prepend or append
string will be added to the job in the appropriate position.)
TEXT
Queue
data in the text queues as unformatted or ASCII text, and adds a
Type
carriage return to each line before sending it to the printer.
AUTO
to determine whether the print data should be sent as raw or
text.
BINPS
to generate the print data using all possible byte values, from 0
to 255. (Most printers using LPR printing use the standard
ASCII range, from 0 to 127.)
Default
Name of the queue to be used if the queue specified for a print job is
Queue
unknown.
Name
Name of a character string. You may define up to eight character
strings for use in LPD queues; this parameter names the string, and the
next parameter defines the content of the string. Prepend and append
String
string names (specified in the table at the top of the window) must be
Name
chosen from the names specified here. The string name can be up to
32 characters long, and can consist of any displayable ASCII
characters.
LPD Queues
: No processing. The line printer daemon treats the data in
: Carriage return added. The line printer daemon treats
: Automatic. The line printer daemon uses auto-sensing
: Binary PostScript. This instructs the PostScript driver

Hide quick links: