GaS Dryer POWer HOOKUP

ELECTRICAL REQUIREMENTS
120 Volt, 60 Hz, AC only, 15- or 20- amp fused electrical
n
supply is required. A time-delay fuse or circuit breaker is
recommended. It is also recommended that a separate circuit
serving only this dryer be provided.
GAS SUPPLY REQUIREMENTS
GAS TYPE
Natural Gas:
This dryer is equipped for use with Natural gas. It is design-
certified by CSA International for LP (propane or butane) gases
with appropriate conversion.
Your dryer must have the correct burner for the type of gas
n
in your home. Burner information is located on the rating
plate in the door well of your dryer. If this information does
not agree with the type of gas available, contact your dealer
or call the phone numbers referenced in the "Assistance or
Service" section of your Use and Care Guide.
LP Gas Conversion:
IMPORTANT: Conversion must be made by a qualified
technician.
No attempt shall be made to convert the appliance from the gas
specified on the model/serial rating plate for use with a different
gas without consulting your gas company.
GAS SUPPLY LINE
Must include 1/8" NPT minimum plugged tapping accessible
n
for test gauge connection, immediately upstream of the gas
connection to the dryer. See illustration.
1/2" IPS pipe is recommended.
n
3/8" approved aluminum or copper tubing is acceptable for
n
lengths under 20 ft. (6.1 m) if local codes and gas supplier
permit.
If you are using Natural gas, do not use copper tubing.
n
Lengths over 20 ft. (6.1 m) should use larger tubing and a
n
different size adapter fitting.
If your dryer has been converted to use LP gas, 3/8" LP
n
compatible copper tubing can be used. If the total length of
the supply line is more than 20 ft. (6.1 m), use larger pipe.
NOTE: Pipe-joint compounds that resist the action of LP gas
must be used. Do not use TEFLON
Must include shut-off valve
n
†®TEFLON is a registered trademark of E.I. Dupont De Nemours and Company.
tape.
®†