SERIAL FUNCTIONAL SPECIFICATION
8. State Read Command
8.1. Format
1) Computer issues commands fin format as below.
"CR" COMMAND [CR]
Command: 1 character (See Status Read Command Table)
2) When a projector receives the appropriate command, it returns a character line as the
required data.
Required Data [CR]
Required Data: A character line (See Status Read Command Table)
3) When receiving data cannot be decode, the projector returns, ""?" [CR].
8.2. Transfer Example
Get input mode for the projector by basic commands.
PC
! Projector
Projector ! PC
8.3. Status Read Command
Command
Detail
Response
【Response Detail】
1) "00" [CR]
Status: POWER ON
The image is displayed normally.
"C"
"CR0" [CR]
Get the projector status
Acceptable
"%1" [CR]
"00" = POWER ON
"80" = STANDBY
"40" = Processing Count Down
"20" = Processing Cooling Down
"10" = Power Failure
%1
"28" = Processing cooling down due to abnormal temperature
"08" = Abnormal Temperature
"88" = normal after recovering abnormal temperature
"24" = Processing Power Save / Cooling Down
"04" = Power Save
Unacceptable
"?" [CR]
COMMAND (current input mode command issue)
"R" "1" CR
←―――→
(A few ms--1s)
(Shows
Computer is selected)
Page 15 of 18
"1"
CR
Response