Before calling for service, review this list. It may save both time and expense. The list includes common
occurrences that are not the result of defective workmanship
or materials in this Wyer.
OCCURRENCE
POSSIBLE CAUSE
SOLUTION
Dryer does not start.
Electrical power cord is not securely plugged
Make sure the plug fits tightly in wall outlet.
in or plug may be loose.
House fuse blown or circuit breaker tripped.
Reset circuit breaker or replace fuse.
Make sure electrical line is not overloaded
and the
dryer is on a separate circuit.
Thermal limiter tripped.
Call authorized service person for replacement.
LCD displays
Dryer has been programmed to temporarily
To return to the factory default settings, select RESET
£1 n'3n
LtLC_l ru
n'3_'3n
-
,,,uuL.
perform a repeating demo cycle,
in set prefs under the options
scroll buttons.
Dryer runs but won't
There are 2 house fuses in the dryer circuit. If 1
Replace fuse.
heat.
of the 2 fuses is blown, the drum may turn but
the heater will not operate. (electric models)
Gas supply valve is not open (gas models).
Check to make sure supply valve is open. See INSTAL-
LATION INSTRUCTIONS for procedure.
Dryer does not have enough air supply to
See INSTALLATION INSTRUCTIONS.
support the burner flame (gas models).
LP gas supply tank is empty or there has
Refill or replace tank.
been a utility interruption
of natural gas (gas
Dryer should heat when utility service is restored.
models).
Drying cycle takes too
Lint filter is clogged with lint.
Make sure all lint has been removed from the dryer lint
long, outside of the
filter before starting each cycle.
dryer feels too hot or
smells hot.
Exhaust duct requirements
have not been
Exhaust duct must be at least 4 inches in diameter and
met.
made of rigid or semi-rigid
metal.
When in place, the duct must have no more than
two 90 ° bends and must not exceed length listed in
INSTALLATION INSTRUCTIONS.
Electric dryer is connected
to a 208 volt
Drying time will be 20% longer than drying on a 240
circuit,
volt circuit.
Drying procedures
have not been followed.
See "Operating
Instructions."
Outside exhaust hood or exhaust duct may
Clean out any obstruction.
be clogged or restricted.
High humidity.
Use a dehumidifier
near the dryer.