Table 41
Parameter
Critical
Warn
Info
None
level [filter]
Specifies the severity level given by [filter] to use in monitoring and logging events for the
specified components or ports.
Table 42
Parameter
Critical
Warn
Info
None
port [port_list]
Specifies one or more ports to monitor for events.
parameters.
Table 43
Parameter
[port_list]
All
None
212 Command reference

Event display filter parameters

Description
Critical severity-level events. The critical level describes events that are generally
disruptive to the administration or operation of the fabric, but require no action.
Warning severity-level events. The warning level describes events that are
generally not disruptive to the administration or operation of the fabric, but are
more important than the informative-level events.
Informative severity-level events. The informative level describes routine events
associated with a normal fabric.
Specifies no severity levels for display on the screen

Severity level monitoring parameters

Description
Monitors critical events. The critical level describes events that are generally
disruptive to the administration or operation of the fabric, but require no action.
This is the default severity level.
Monitors warning and critical events. The warning level describes events that are
generally not disruptive to the administration or operation of the fabric, but are
more important than the informative level events.
Monitors informative, warning, and critical events. The informative level describes
routine events associated with a normal fabric.
NOTE:
resources because of the high volume of events.
Monitors none of the severity levels

Port monitoring parameters

Description
Specifies the port or ports to monitor. [port_list] can be a set of port numbers and
ranges delimited by spaces. For example, 0 2 10-15 specifies ports 0, 2, 10,
1 1, 12, 13, 14, and 15.
Specifies all ports
Disables monitoring on all ports
Table 42
describes the severity level monitoring parameters.
Logging events at the Info severity level can deplete switch
Table 43
describes the port monitoring

Advertisement