Table 16
Parameter
RecipientMail
CaptureEnabled
Operands
delete [profile]
Deletes the specified profile given by [profile] from the Call Home database. You must enter the
callhome save command to save your changes.
edit [profile]
Opens an edit session in which to change the configuration of an existing profile given by
[profile]. The Tech_Support_Center profile can be edited. For descriptions of the profile
parameters, see
the Tech_Support_Center profile.
rename [profile_old] [profile_new]
Renames the profile given by [profile_old] to the profile given by [profile_new]. You must enter the
callhome save command to save your changes.
Examples The following is an example of the profile create command:
8/20q FC Switch #> admin start
8/20q FC Switch (admin) #> callhome edit
8/20q FC Switch (admin-callhome) #> profile create profile_1
A list of attributes with formatting and default values will follow.
Enter a new value or simply press the ENTER key to accept the current value.
If you wish to terminate this process before reaching the end of the list
press 'q' or 'Q' and the ENTER key to do so.
Default Values:
Level
Format
MaxSize
EmailSubject
RecipientEmail
New Value (press ENTER to accept default value, 'q' to quit):
Level
Format
MaxSize
EmailSubject
RecipientEmail
1. <undefined>
The profile has been created.
This configuration must be saved with the callhome save command
before it can take effect, or to discard this configuration
use the callhome cancel command.
8/20q FC Switch (admin-callhome) #> callhome save
The CallHome database profiles will be saved and activated.
Please confirm (y/n): [n] y
182 Command reference
Profile configuration parameters (continued)
Description
Addresses to send e-mail messages to; maximum of 10 addresses. The
address format is account@domain.
Enables (True) or disables (False) the data capture configuration only
when creating the Tech_Support_Center profile. The default is False. For
more information about the data capture configuration, see the "capture"
command.
Table
16. The CaptureEnabled parameter is displayed only when modifying
Alarm
FullText
100000
<undefined>
(up to 10 entries allowed)
(Alarm,Critical,Warn,None)
(1=FullText, 2=ShortText)
(decimal value, 650-2000000)
(string, max=64 chars, N=None)
(ex: admin@company.com, N=None)
:
:
:
: Technical problem
: admin0@company.com