Fabric OS 6.2.2a fixes
Table 12
lists defects closed in the Fabric OS 6.2.2a firmware release.
Table 12 Fabric OS 6.2.2a closed defects
Closed defect summary
After a target port bounce, the FC FastWrite host cannot recognize
the target due to a cam setup problem on the backend port used by
FC FastWrite.
After upgrading to Fabric OS 6.2.x, the 400 MP Router or Multipro-
tocol Router blade detects a credit problem on virtual channel 0,
causing a frame drop on FCIP and FC FastWrite, and the host is unable
to recognize the target.
While running Fabric OS 6.2.2, the switch can panic after executing
a fcplunquery or iscsicfg CLI command for the target entity on
HP StorageWorks iSCSI Director Blade. An FCPD termination occurs
if a PRLI or Report LUN query times out during fcplunquery/isc-
sicfg command and the LOGO response is missing a message queue
required for processing, resulting in a switch panic.
Fabric class areas > Zoning Changes in fwconfigure does not
function correctly. Zone changes are not recorded in the FW module,
resulting in threshold alarms not being raised as appropriate.
After using the ipaddrset -cp command to set a CP blade or dir-
ector switch host name, the standby CP incorrectly displays the CP
host name instead of the chassis host name. For the change to take
effect, after upgrading the firmware, the user must logout, and then
log back in.
During reboot, HP StorageWorks D2D Backup System device sends
the explicit logout; however, the switch does not clean up the route
properly, resulting in the hosts being unable to detect the tape devices.
Username/password authentication can fail when using Microsoft
Active Directory (LDAP) from Server 2008 for authentication. Users
can experience problems after upgrade from a Microsoft Windows
host using older versions of the LDAP protocol for authentications.
After using the snmpconfig -set snmpv command to set SNMPv3,
the switch configdownload command failed with the following
message: snmp.snmpv3Usm.0.usmPrivProtocol:6 Invalid
Value.
If you set fwsettocustom, the HP StorageWorks DC SAN Backbone
Director does not output FW-1003/FW-1004 after an hafailover or
reboot, and you will not be notified about temperature over threshold
events.
The systemverification and portloopbacktest diagnostic tests report
marginal blade failures on an HP StorageWorks DC SAN Director,
but after the tests are complete, Fabric Watch reports switch is healthy.
46
Solution
Fixed in Fabric OS 6.2.2a
Fixed in Fabric OS 6.2.2a
Fixed in Fabric OS 6.2.2a
Fixed in Fabric OS 6.2.2a
Fixed in Fabric OS 6.2.2a
Fixed in Fabric OS 6.2.2a
Fixed in Fabric OS 6.2.2a
Fixed in Fabric OS 6.2.2a
Fixed in Fabric OS 6.2.2a