Layer 2 configuration

The following table describes the Layer 2 Configuration commands. The following sections provide more
detailed information and commands.
Layer 2 Configuration commands
Table 100
Command
vlan {<1-4094>}
[no] spanning-tree uplinkfast Enables or disables Fast Uplink Convergence, which provides rapid
spanning-tree uplinkfast max-
update-rate <10-200>
show layer2

802.1x configuration

This feature allows you to configure the HP 10GbE switch as an IEEE 802.1x Authenticator, to provide
port-based network access control. The following table describes the 802.1x Configuration commands.
802.1x Configuration commands
Table 101
Command
dot1x enable
no dot1x enable
show dot1x
Description
Enter VLAN configuration mode.
Command mode: Global configuration
Spanning Tree convergence to an upstream switch during failover.
When enabled, this feature increases bridge priorities to 65500
NOTE:
for all STGs and path cost by 3000 for all external STP ports.
Command mode: Global configuration
Configures the station update rate, in packets per second.
The range is 10-200. The default value is 40.
Command mode: Global configuration
Displays current Layer 2 parameters.
Command mode: All
Description
Globally enables 802.1x.
Command mode: Global configuration
Globally disables 802.1x.
Command mode: Global configuration
Displays current 802.1x parameters.
Command mode: All