Lenovo 410554U Hardware Maintenance Manual page 69

User manual
Hide thumbs Also See for 410554U:
Table of Contents

Advertisement

Diagnostic Error Code
030-196-XXX SCSI interface test halt, error threshold
exceeded
030-197-XXX SCSI interface test warning
030-198-XXX SCSI interface test aborted
030-199-XXX SCSI interface test failed, cause unknown
035-000-XXX RAID interface Test Passed
035-0XX-XXX RAID interface Failure
035-195-XXX RAID interface Test aborted by user
035-196-XXX RAID interface test halt, error threshold
exceeded
035-197-XXX RAID interface test warning
035-198-XXX RAID interface test aborted
035-199-XXX RAID interface test failed, cause unknown
071-000-XXX Audio port Interface Test Passed
FRU/Action
1. Press F3 to review the log file
2. Re-start the test to reset the log file
1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 "Using
the Setup Utility" on page 39
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6 "Using
the Setup Utility" on page 39
2. Flash the system and re-test. See "Flash update
procedures" on page 259
3. Go to "Undetermined problems" on page 73
1. Go to "Undetermined problems" on page 73
2. Flash the system and re-test. See "Flash update
procedures" on page 259
3. Replace component under function test
No action
1. RAID signal cable
2. RAID device
3. RAID adapter card, if installed
4. System board
Information only Re-start the test, if necessary
1. Press F3 to review the log file
2. Re-start the test to reset the log file
1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 "Using
the Setup Utility" on page 39
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6 "Using
the Setup Utility" on page 39
2. Flash the system and re-test. See "Flash update
procedures" on page 259
3. Go to "Undetermined problems" on page 73
1. See "Undetermined problems" on page 73
2. Flash the system and re-test. See "Flash update
procedures" on page 259
3. Replace component under function test
No action
Chapter 9
.
Symptom-to-FRU Index
63

Advertisement

Table of Contents
loading

Table of Contents