Detailed Parts Guide; Cleaning; Maintaining The Cleanliness Of Your Breast Pump; How To Assemble The Manual Breast Pump - Philips SCF310/20 User Manual

Manual breast pump
Hide thumbs Also See for SCF310/20:
Table of Contents

Advertisement

Available languages

Available languages

EN

2. Detailed parts guide

MANUAL BREAST PUMP
a)
Funnel cover/Stand
b)
Let-down Massage Cushion
c)
Pump cover
d)
Silicone diaphragm and stem*
e)
Handle
f)
Pump body
g)
White valve*

3. Cleaning

Before you use your breast pump for the first time and every time
before use:
Separate all parts, then wash in the dishwasher or in warm soapy
water. Do not use antibacterial cleaners/detergents.
Caution: Take care when cleaning the white valve.
If it gets damaged, your breast pump will not function
properly. To clean the white valve, rub it gently
between your fingers in warm soapy water. Do not
insert objects as this may cause damage.

4. Maintaining the cleanliness of your breast pump

After cleaning all parts, insert the white valve (g) and fit the
diaphragm with stem (d) onto the pump body (f). Clip the
cover (a) over the funnel and Let-down Massage Cushion (b)
and screw on the sealing base (m) in place of the Philips AVENT
feeding bottle (h).
2
BOTTLE
h)
Philips AVENT feeding bottle (4oz/125ml)
or
adaptor ring
i)
Stand (same as a)
j)
Dome cap
k)
Extra Soft Nipple, Newborn Flow (0m+)
l)
Screw ring
m)
Sealing base
n)
Sealing disc
*spares included
5.

How to assemble the manual breast pump

Please refer to diagram 6 at the beginning of this leaflet. Separate all
parts and ensure pump has been cleaned as in section 3:
1)
Wash your hands thoroughly. Click the white valve (g) into the pump body
(f) from underneath.
2)
Place the pump body (f) onto the Philips AVENT feeding bottle (h).*
3)
Twist gently clockwise until secure. DO NOT OVERTIGHTEN!
4)
Place the silicone diaphragm with stem (d) into the pump body (f).
Make sure it fits securely round the rim by pressing down with your
fingers to ensure a perfect seal. (This is easier if assembled while wet.)
5)
Place the forked end of the handle (e) under the silicone diaphragm and
stem (d) and push down gently on the handle until it clicks into place.
6)
Carefully insert the Let-down Massage Cushion (b) into the pump funnel
(f) making sure it is perfectly sealed all round the rim of the funnel.
(This is easier if assembled while wet.)
7)
Click the pump cover (c) onto the pump body (f). To make the pump
completely stable insert the bottle into the stand (a).
*ALWAYS insert the adaptor ring when using a polypropylene bottle
EN
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scf310/13

Table of Contents