2001/10/02
6.2.

Variables

6.2.1.
1.
The PJL environment variables which are not printer language-specific are listed in the following table. When
using these variables, do not use LPARM.
Variables
COPIES
MANUALFEED
ECONOMODE
ECONOLEVEL
PERSONALITY
INPUTBUF
XOFFSET
YOFFSET
AUTOCONT
TIMEOUTEMU
PRIORITY
HPFSEL
AUTOFF
TIMEOUTFF
TIMEOUT
CDCCHIGH
DTRCTRL
AUTOSLEEP
TIMEOUTSLEEP
IBMCHARE1
Variables for HL-1050/1070/1250/1270N/1450/1470N/P2500/1670N/3260N/2460
General PJL Environment Variables
Description
Number of uncollated copies for each
page of the job.
Feeds the paper from manual feed slot.
Turn the economy mode (toner saving
mode) ON or OFF.
Selects the toner saving level from 1
(high) to 3 (low).
Sets the emulation mode.
Sets the receiving buffer size value.
Sets the X offset ( horizontal offset )
value.
Sets the Y offset ( vertical offset ) value.
Auto Continue Mode
Sets the time-out value for automatic
emulation switching.
Sets the priority between EPSON or IBM
for automatic emulation switching.
Sets the auto FF setting to ON or OFF.
Sets the timeout value for auto FF.
Sets the timeout value for Automatic
interface switching
Sets the high-speed transfer mode of the
Centronics interface to ON or OFF.
Selects when DTR becomes low.
0 = the printer is turned off-line by the SEL
switch, the input buffer is full, or when a
printer error occurs.
1 = the printer is turned off-line by the SEL
switch or when a printer error occurs.
2 = the printer is turned off-line by the SEL
switch.
Sets the automatic sleep mode ON or
OFF.
Sets the timeout value for automatic
sleep mode.
CHAPTER 5 PJL - 18
Sample Value Range
1 to 200 (HL-1050/1070)
1 to 99
(HL-
1250/1270N/1450/1470N/P2500)
1 to 999 (HL-1670N/3260N/2460)
ON or OFF
ON or OFF
1 to 3
0 to 3
(HL-1670N/3260N/HL-2460)
AUTO, PCL, IBM, EPSON,
POSTSCRIPT (All models)
HPGL (HL-3260N/2460)
1 to 15 (HL-2460)
-500 to 500 dots
(HL-
1050/1070/1250/1270N/1450/1470N/
P2500/1670N/2460
-104 to 500 (HL-3260N)
-500 to 500 dots
ON or OFF
1 to 99 seconds
EPSON or IBM
ALL, LJ4 (HL-2460)
ON or OFF
1 to 99 seconds
1 to 99 seconds
ON or OFF
(HL-
1050/1070/1250/1270N/1450/1470N/
P2500)
0 to 2
(HL-
1050/1070/1250/1270N/1450/1470N/
P2500/1670N)
ON or OFF
1 to 00 minutes
1 to 99 minutes (HL-1670N/2460)
1 to 240 minutes (HL-3260N)
BETA or ESSZET