HP 316095-B21 - StorageWorks Edge Switch 2/24 User Manual page 222

Fw 07.00.00/hafm sw 08.06.00 hp storageworks ha-fabric manager user guide (aa-rs2cf-te, march 2005)
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

Table 24
Element Manager Messages (continued)
Message
The link to the director is
not available.
The link to the switch is
not available.
The IPL configuration
cannot be deleted.
The management server
is busy processing a
request from another
Element Manager.
The optical transceiver is
not installed.
The switch did not accept
the request.
The maximum number of
address configurations
has been reached.
The switch did not
respond in the time
allowed.
The switch is busy saving
maintenance information.
222
Informational and error messages
Description
The Ethernet connection
between the HAFM
appliance and the
director is down or
unavailable.
The Ethernet connection
between the HAFM
appliance and the switch
is down or unavailable.
Deletion of the IPL
address configuration
was attempted and was
not allowed.
The HAFM appliance is
processing a request from
another instance of an
Element Manager, and
cannot perform the
requested operation.
Information is not
available for a port
without an optical
transceiver installed.
The director or switch
cannot perform the
requested action.
The maximum number of
saved address
configurations has been
reached.
While waiting to perform
a requested action, the
director or switch timed
out.
The director or switch
cannot perform the
requested action because
it is busy saving
maintenance information.
Action
Establish and verify the network
connection.
Establish and verify the network
connection.
Cancel the operation.
Wait until the process completes,
then perform the operation again.
Install an SFP optical transceiver in
the port.
Retry the operation. If the condition
persists, contact the next level of
support.
Delete configurations no longer
needed to allow new configuration
to be saved.
Retry the operation. If the condition
persists, contact the next level of
support.
Retry the operation later. If the
condition persists, contact the next
level of support.

Advertisement

Table of Contents
loading

Table of Contents