6.1.4 Response to diagnostic command

When the master device receives an EXECUTE DEVICE DIAGNOSTIC
command and the slave device is present, the master device checks the PDIAG-
signal for up to 6 seconds to see if the slave device has completed the self-
diagnosis successfully.
The master device does not check the DASP- signal.
After the slave device receives the EXECUTE DEVICE DIAGNOSTIC
command, it shall report the result of the self-diagnostics to the master device as
described below:
PDIAG- signal: negated within 1 ms and asserted within 5 seconds
The asserted PDIAG-signal is negated 5 seconds after it is asserted if the
command is not received. If the command is received, the PDIAG-signal is
negated according to timing at which the command is received.
When the IDD is set to a slave device, the IDD asserts the DASP- signal when
negating the PDIAG- signal.
X'1F7' Reg.
Write
Master device
Status Reg.
BSY bit
Slave device
BSY bit
PDIAG-
DASP-
Figure 6.4 Response to diagnostic command
6-6
Max. 6 sec.
If the slave device is preset, PDIAG- signal is checked for
up to6 seconds.
Max. 1 ms.
Max. 5 sec.
C141-E171-03EN