Fujitsu MHM2100AT - Mobile 10 GB Hard Drive Product Manual page 189

Disk drives
Hide thumbs Also See for MHM2100AT - Mobile 10 GB Hard Drive:
Table of Contents

Advertisement

Interface
Table 5.18 Ultra DMA data burst timing requirements (2 of 2)
NAME
MODE 0
MODE 1
(in ns)
MIN
MAX
MIN
t
0
0
ZIORDY
t
20
20
ACK
t
50
50
SS
Notes:
1) Unless otherwise specified, timing parameters shall be measured at the connector of the sender or receiver to which the parameter
applies (see Note 5 for exceptions). For example, the sender shall stop generating STROBE edges t
DMARDY-. Both STROBE and DMARDY- timing measurements are taken at the connector of the sender.
2) All timing measurement switching points (low to high and high to low) shall be taken at 1.5 V.
3) t
, t
and t
indicate sender-to-recipient or recipient-to-sender interlocks, i.e., one agent (either sender or recipient) is waiting for
UI
MLI
LI
the other agent to respond with a signal before proceeding. t
limited time-out that has a defined minimum. t
4) Special cabling shall be required in order to meet data setup (t
5) Timing for t
and t
shall be met for all capacitive loads from 15 to 40 pf where all signals have the same capacitive load value.
DVS
DVH
5-112
MODE 2
(in ns)
(in ns)
MAX
MIN
MAX
MIN
0
0
20
20
50
50
is an unlimited interlock that has no maximum time value. t
UI
is a limited time-out that has a defined maximum.
LI
DS
MODE 3
MODE 4
(in ns)
(in ns)
MAX
MIN
MAX (see Notes 1 and 2)
0
Minimum time before driving
IORDY
20
Setup and hold times for DMACK-
(before assertion or negation)
50
Time from STROBE edge to
negation of DMARQ or assertion of
STOP (when sender terminates a
burst)
) and data hold (t
) times in modes 3 and 4.
DH
COMMENT
after the negation of
RFS
is a
MLI
C141-E104-03EN

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mhm2200atMhm2150atMhl2300at

Table of Contents