Turn Main Switch off. Turn appliance off.
Plug appliance into the 12V DC Outlet, then turn on. When finished, turn off then unplug appliance.
5.6.
CHARGING/POWERING USB DEVICES
Press TEST Button to check battery level. Recharge as needed, according to Charging section.
Plug the device into the USB Port.
Press the LIGHT/USS Button. The USB Indicator will illuminate.
When finished, press LIGHT/USS Button again. Remove the device from the USB Port. NOTE: USB Port stops working when battery
voltage level drops below 11V.
5.7.
IN EVENT OF BREAKDOWN: Remove from use. Professional repair only.
6. MAINTENANCE
6.1.
Procedures not specifically explained in this manual must be performed only by a qualified technician.
WARNING! TO PREVENT SERIOUS INJURY: Unplug Roadstart®, turn the Main Switch off and allow to cool completely before
performing any inspection, maintenance, or cleaning procedures.
BEFORE EACH USE, inspect the general condition of the Jump Starter. Check for:
6.2.
• loose hardware
• cracked or broken parts
• damaged electrical wiring or cable insulation
• any other condition that may affect its safe operation.
6.3.
Keep unit clean and clamps free of dirt, debris, or grease.
6.4.
For longer working life, protect unit from sunlight and moisture.
6.5.
AFTER USE, wipe external surfaces with a clean cloth.
6.6.
RECOMMENDED MAINTENANCE:
Recharge jump-start after every usage.
Recharge every 3 months as regular maintenance.
7. END OF LIFE
WARNING! TO PREVENT SERIOUS INJURY: CONTAINS NON-SPILLABLE, SEALED LEAD- ACID BATTERY. BATTERY MUST
BE RECYCLED OR DISPOSED OF PROPERLY.
7.1.
BATTERY DISPOSAL: Contains batteries that are only replaceable by skilled persons.
7.1.1.
Disposal must comply with standards for hazardous waste disposal in your area.
8. TROUBLESHOOTING
Display
Alarm Issue
Er1
Yes
Er2
Yes
Hi
Yes
LO
Yes
%, Voltage, Lo,
Yes
CHG
Voltage Lo, CHG
Yes
Voltage, Lo, CHG
Yes
© Jack Sealey Limited
Issue Information
Protection
Reversed Polarity
Protection
Protection
External Battery Voltage is
Higher than 30V DC
Protection
Internal Battery Voltage is
higher than 15V DC
Protection
External battery voltage is
lower than 6V DC
Alert
Reminder that internal
battery
Level is lower than 11.5V
DC and needs to be
recharged
Alert
Reminder that the internal
battery level is lower than
11.5V DC and needs to be
recharged.
Urgent
Reminder that internal
battery is lower than
11v DC and needs to be
recharged.
Original Language Version
Correction
Disconnect the clamps from the battery posts. Then properly
reconnect the clamps to the battery
Posts(+) to(+) and(-) to (-)/Grounded terminal.
Disconnect the clamps from the external
Battery. Correct the external high voltage issue of the external battery.
Unplug the charger, if battery is being recharged. Have the product
evaluated and repaired by a qualified technician.
Disconnect the clamps from the external battery.
Roadstart® only works with 12V battery system.
Press test button to reset the alarm. Recharge the Roadstart®. All
functions are working.
Press test button to reset the alarm. Recharge. Only light and USB
are working.
Press "TEST" button to reset the alarm.
Recharge. None of the functions are working.
PRS2200 PRS4400 Issue:1 05/06/25
Need help?
Do you have a question about the PREMIER ROADSTART PRS2200 and is the answer not in the manual?