Venting; Venting Requirements - Whirlpool WED8200YW Installation Instructions Manual

Installation guide
Hide thumbs Also See for WED8200YW:
Table of Contents

Advertisement

2.
Connect neutral ground wire
and neutral wire
Connect neutral ground wire (E) and neutral wire (white or
center wire) (C) of power supply cord or cable under center
terminal block screw (B). Tighten screw.
3.
Connect remaining wires
Place hooked ends of remaining wires under outer terminal
block screws (hooks facing right). Tighten screws.
4.
Connect external ground wire
Connect a separate copper ground wire (G) from the external
ground conductor screw (A) to an adequate ground. Finally,
reinsert tab of terminal block cover into slot of dryer rear
panel. Secure cover with hold-down screw. Now, go to

"Venting Requirements".

12

VENTING

VENTING REQUIREMENTS
B
E
C
WARNING:
To reduce the risk of fire, this dryer MUST BE
EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances.
Dryer exhaust must not be connected into any gas vent,
chimney, wall, ceiling, attic, crawlspace, or a concealed space
of a building. Only rigid or flexible metal vent shall be used for
exhausting.
4" (102 mm) heavy metal exhaust vent
Only a 4" (102 mm) heavy metal exhaust vent and clamps
may be used.
Do not use plastic or metal foil vent.
A
Rigid metal vent:
Recommended for best drying performance and to avoid
crushing and kinking.
G
Flexible metal vent:
Must be fully extended and supported in final dryer location.
Remove excess to avoid sagging and kinking that may
result in reduced airflow and poor performance.
Do not install in enclosed walls, ceilings, or floors.
The total length should not exceed 7
NOTE:
If using an existing vent system, clean lint from
entire length of the system and make sure exhaust hood
is not plugged with lint. Replace plastic or metal foil vents
with rigid metal or flexible metal vents. Review Vent System
Chart and if necessary, modify existing vent system to
achieve best drying performance.
4"
(102 mm)
(Acceptable only if accessible to clean)
/
ft. (2.4 m).
3
4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents