Electrical: A four-wire or three-wire, single phase,
120/240-volt, 60-Hz, AC-only, electrical supply (or
120/208-volt electrical supply, if specified on the
serial/rating plate) is required on a separate 30 amp
circuit, fused on both sides of the line. Use 10
gauge solid copper wire. A time-delay fuse or circuit
breaker is recommended.
Exhaust venting: Exhaust your dryer to the
outside. Four-inch diameter vent is required. Rigid
or flexible metal exhaust vent must be used. Do not
use plastic or metal foil vent. Exhaust outlet hood
must be at least 12 inches from the ground or any
object that may be in the path of the exhaust.
EXHAUST VENTING
Number of
Type of
Box or
90° turns
vent
Louvered
or elbows
hoods
0
Rigid metal
64 ft (20 m)
Flexible metal
36 ft (11 m)
1
Rigid metal
54 ft (16.5 m)
Flexible metal
31 ft (9.4 m)
2
Rigid metal
44 ft (13.4 m)
Flexible metal
27 ft (8.2 m)
3
Rigid metal
35 ft (10.7 m)
Flexible metal
25 ft (7.6 m)
4
Rigid metal
27 ft (8.2 m)
Flexible metal
23 ft (7 m)
NOTE: Side and bottom exhaust installations have a 90° turn
inside the dryer. To determine maximum exhaust length, add one
90° turn to the chart.
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.

Electric Dryer

OVERALL DIMENSIONS
RECESSED AREA AND CLOSET INSTALLATION
18"
(45.7 cm)
0"*
(0 cm)
*Additional spacing recommended
Recommended hood styles
Angled
hoods
58 ft (17.7 m)
28 ft (8.5 m)
48 ft (14.6 m)
23 ft (7 m)
38 ft (11.6 m)
19 ft (5.8 m)
A . Louvered hood style
B . Box hood style
29 ft (8.8 m)
17 ft (5.2 m)
21 ft (6.4 m)
Select the route that will provide the straightest and most direct path
15 ft (4.6 m)
outdoors. Plan the installation to use the fewest number of elbows and turns.
Avoid making 90° turns.
Do not use vent runs longer than specified in vent length chart.
Determine the number of elbows you will need.
15¼"
(38.74cm) 43³⁄₈"
43³⁄₈"
(110cm)
*26"
(66cm)
29"
(73.66cm)
A
22¾"
(57.8cm)
43³⁄₈"
(110cm)
*27¾"
(70.5cm)
29"
(73.66cm)
C
A. Small opening side-swing door
B. Large opening side-swing door
C. Wide opening side-swing door
D. Wide opening hamper door
14" max.
(35.6cm)
29"
0"*
27¾"
5½"
0"*
(0 cm)
(70.5 cm)
(73.66 cm)
(0 cm)
B
A
Angled hood style is
B
(10.2 cm)
A
4"
(10.2 cm)
4"
(10.2 cm)
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
(57.8cm)
(110cm)
*27¾"
(70.5cm)
29"
(73.66cm)
B
43³⁄₈"
(110cm)
*27¾"
(70.5cm)
29"
(73.66cm)
D
* Most installations require a
3"
(7.6 cm)
48 in.
2
2
(310 cm )
For closet installation with a
door, minimum ventilation
openings in the top and bottom
of the door are required.
Louvered doors with equivalent
2
24 in.
air openings are acceptable.
3"
2
(155 cm )
(7.6 cm)
(14 cm)
A. Recessed area
C
B. Side view - closet or confined area
C. Closet door with vents
acceptable.
4"
2.5"
(6.4 cm)
22¾"
13¾"
(34.9cm)
minimum 5 " (14 cm)
clearance behind the dryer for
the exhaust vent with elbow.
Ref. 8577188