Download Print this page

Kenmore 9875 - 24 in. Laundry Center Owner's Manual And Installation Instructions page 29

24-inch wide laundry center washer-gas dryer

Advertisement

1-his laundry center may be converted
o exhaust out the right or left side. To
;onvert the laundry center, one of the
following kits MUST be used.
Side Exhaust Kit No. 3391335 (white)
Side Exhaust Kit No. 3391336 (almond)
Follow the instructions
in the kit to
avoid operational
and personal hazards.
These kits are available at your local
Sears store or Sears Service Center.
Typical installations
for left or right side
exhausting
DETERMINE
VENT
LENGTH
Maximum Exhaust Lengths:
• Rear Exhaust. The maximum length
of the rear exhaust system depends
on the type of vent, the number of
elbows and the type of exhaust hood.
Refer to the chart below.
• Side Exhaust. Side exhaust adds
a 90 ° turn inside the laundry center.
To determine
maximum exhaust
length, add one 90 ° turn to the chart.
EXHAUST HOOD TYPE
Number of
Maximum length of 4-inch
90° Turns diameter rigid heavy metal vent.
0
36 ft.
34 ft.
29 ft.
1
26 ft.
24 ft.
20 ft.
2
16ft.
14ft.
12ft.
Number of
Maximum length of 4-inch
90° Turns diameter flexible heavy metal vent.
0
22 ft.
21 ft.
16 ft.
1
16ft.
15ft.
10ft.
2
8ft.
7ft.
2ft.
NOTE: Avoid pushing the laundry center
tightly against a wall. This can crush or
kink the vent. Use the straightest path you
can, where possible, to avoid 90 ° turns.