Kenmore 9791 - 27 in. Laundry Center Installation Instructions Manual page 5

27" (69 cm) wide laundry center washer- dryer
Hide thumbs Also See for 9791 - 27 in. Laundry Center:

Advertisement

Available languages

Available languages

Thelaundry center m aybeexhausted four(4)wayswithrear
flushinstallation:
1.
Straight back
2. Down (8 inch [20.32 cm] length of 4 inch [10.16 cm] rigid
duct and 1 elbow down)
3. Left (8 inch [20.32 cm] length of 4 inch [10.16 cm] rigid
duct, 1 elbow down and 1 elbow left)
4. Right (8 inch [20.32 cm] length of 4 inch [10.16 cm] rigid
duct, 1 elbow down and 1 elbow right)
To exhaust up, add an 11 inch (27.94 cm) length of standard 4
inch (10.16 cm) diameter duct and a 90 ° elbow. The unit will
be positioned about 41/2inches (11.43 cm) away from the wall
(flush to wall exhausting may be done by going below the dryer
then sideways).
An exhaust hood positioned
to line up with the dryer
exhaust
can be installed
directly through the outside
wall. To exhaust to the side
or down,
add an 8 inch
(20.32 cm) length of standard
4 inch (10.16 cm) diameter
duct and a 90 ° elbow.
DO NOT INSTALL YOUR LAUNDRY CENTER:
......
1.Installation MUST conform with local codes, or in the absence
of local codes, with the National Fuel Gas Code, ANSI Z223.1
(latest edition) or in Canada, the current AN/CGA B149.
2.The gas supply line should be of 1/2 inch (1.27 cm) pipe.
3.If codes allow, flexible metal tubing may be used to connect
your dryer to the gas supply line. The tubing MUST be
constructed of stainless steel or plastic-coated brass.
4.The gas supply line MUSThave an individual shutoff valve.
5.A 1/8 inch (0.32 cm) N. F T. plugged tapping, accessible for
test gage connection,
MUST be installed
immediately
upstream of the gas supply connection to the dryer.
6.The dryer and its individual
shutoff
valve MUST
be
disconnected from the gas supply piping system during any
pressure testing of the gas supply piping system at test
pressures equal to or less than 1/2 psig (3.45 kPa).
7.The dryer MUSTbe isolated from the gas supply piping system
by closing its individual manual shutoff valve during any
pressuretesting of the gas supply piping system at test pressures
equal to or less than 1/2 psig (3.45 kPa).
1.In an area exposed to dripping water or outside weather conditions.
2.In an area where it will come in contact with curtains or drapes.
3.On carpet. Floor MUSTbe solid with a maximum slope of 1 inch (2.54 cm).
INSTALLATION IN RECESSOR CLOSET
1.A laundry center installed in a bedroom, bathroom, recess or closet, MUSTbe exhausted outdoors.
2.No other fuel burning appliance shall be installed in the same closet as the Gas laundry center.
3.Your laundry center needs the spacearound it for proper ventilation.
DO NOT INSTALL YOUR LAUNDRY CENTER IN A CLOSET WITH A SOLID DOOR.
4.A minimum of 120 square inches (774.2 square cm) of opening, equally divided at the top and bottom of the door, is required.
Air openings are required to be unobstructed when a door is installed. A Iouvered door with equivalent air openings for the full
length of the door is acceptable.
5.The following illustrations show minimum clearance dimensions and air openings for proper operation in a recess or closet
installation.
0 IN.
0 IN.
1 IN.
; ;
',',
0 IN.
(0
_(0 c
M)
(2.54CM)'I, , _
_(0
CM)
60 SQ.iN.
60SQ._N.
(387.1 SQ. CM)
(387.1 SQ. CM) I_
II
III
(387.1 SQ. CM)
60 SQ. IN.
_
I
Closet Door