CHAPTER 4 DISASSEMBLY AND RE-ASSEMBLY
NOTE:
When re-assembling the fixing unit, align the fixing unit frame at the drive unit side into the
concave part of the main frame.
Fixing unit
(7) Remove the M3x10 screw to remove the star wheel holder ASSY from the fixing unit by
lifting the left hand end of the assembly slightly and then moving the assembly to the right
to release the right hand end from the fixing unit frame.
Fixing unit
Main frame
Fig. 4-30
Fixing unit
Star wheel holder ASSY
Screw, bind M3x10
Fig. 4-31
4-18
Main frame
(concavity)