1.
SAFETY
1.1.
ELECTRICAL SAFETY
WARNING! It is the user's responsibility to check the following:
Check all electrical equipment and appliances to ensure that they are safe before using. Inspect power supply leads, plugs and all
9
electrical connections for wear and damage. Sealey recommend that an RCD (Residual Current Device) is used with all electrical
products.
Electrical safety information. It is important that the following information is read and understood:
Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply.
9
Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that they are secure.
9
IMPORTANT: Ensure that the voltage rating on the appliance suits the power supply to be used and that the plug is fitted with the
correct fuse.
DO NOT pull or carry the appliance by the power cable.
8
The unit shall be installed in accordance with national wiring regulations.
9
DO NOT pull the plug from the socket by the cable.
8
DO NOT use worn or damaged cables, plugs or connectors. Ensure that any faulty item is repaired or is replaced immediately by a
8
qualified electrician.
If the cable or plug is damaged during use, switch off the electricity supply and remove from use.
Ensure that repairs are carried out by a qualified electrician.
1.2.
POWER CORDS
1.2.1. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid
a hazard.
1.3.
GENERAL SAFETY
1.3.1. Read the user manual carefully before operation.
WARNING! Children shall NOT play with the appliance.
Check that the unit is in sound condition and good working order. Take immediate action to repair or replace damaged parts.
9
Use recommended parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
The appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation.
9
NOTE: Only install or operate in a room with a floor area exceeding 7m
DO NOT stand or place any object closer than 500mm (20 inches) from the unit.
8
DO NOT obstruct the air intakes or outlets of the unit.
8
DO NOT cover with items of clothing. DO NOT sit or climb onto the unit.
8
DO NOT place any object onto the unit, or into the outlets.s
8
1.4.
REFRIGERANT
The appliance is designed for use with propane gas R290 only as it's designated refrigerant, and is flammable.
WARNING! No open flames, cigarettes or other possible sources of ignition should be used inside or in the vicinity of the unit.
WARNING! Component parts are designed for propane and non-incentive and non-sparking. Component parts shall only be replaced with
identical repair parts.
FAILURE TO ABIDE BY THIS WARNING COULD RESULT IN AN EXPLOSION, DEATH, INJURY AND, OR PROPERTY DAMAGE.
WARNING! This unit uses flammable refrigerant.
WARNING! The propane gas used in this unit has no odour. The lack of smell does not indicate a lack of escaped gas.
WARNING! If propane gas is present or even suspected, DO NOT allow untrained personnel to attempt to find the cause.
WARNING: The refrigerant loop is sealed. Servicing should only be carried out by a qualified technician.
WARNING! If a leak is detected, immediately evacuate all persons from the room, ventilate the room and contact the local fire
department to advise them that the propane leak has occurred.
DO NOT let any persons back into the room until a qualified service technician has arrived and assessed if it is safe to return to the
8
room.
DO NOT discharge the refrigerant into the atmosphere.
8
WARNING! If refrigerant leaks and comes in contact with fire or heating, it will create harmful gas and there is a risk of fire.
Pipe-work shall be protected from physical damage and shall not be installed in an unventilated space, if that space is smaller than
9
7m².
WARNING! Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from
an industry-accredited assessment authority, which authorizes their competence to handle refrigerants safely in accordance with an
industry, recognized assessment specification.
© Jack Sealey Limited
3-IN-1 PORTABLE AIR CONDITIONING UNIT WITH
WINDOW SEALING KIT 5,000BTU/HR.
MODEL NO:
Indoor use
Caution:
only
risk of fire
Original Language Version
SAC5000, SACWK1
.
2
SAC5000, SACWK1
Issue 1
29/11/24
Table of Contents
loading
Need help?

Need help?

Do you have a question about the SAC5000 and is the answer not in the manual?

Questions and answers

Summary of Contents for Sealey SAC5000

  • Page 1 SAC5000, SACWK1 MODEL NO: Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2 Prior to work taking place, the area around the equipment is to be surveyed to make sure that there are no flammable hazards or ignition risks. “No Smoking” signs shall be displayed. SAC5000, SACWK1 Issue 1 29/11/24 Original Language Version © Jack Sealey Limited...
  • Page 3: Specification

    Nett Weight: 18.5kg Noise Level: 53dB(A) Plug Type: 3-Pin Power Supply Cable Length: 1.8m Power: 560W Rated Capacity: 1460W Refrigerant: R290 Suction Side Pressure: 0.7MPa Supply: 230V - 50Hz SAC5000, SACWK1 Issue 1 29/11/24 Original Language Version © Jack Sealey Limited...
  • Page 4: Installation

    5.3.6. Adjusting the length of the flexible exhaust hose, and avoid bends in the hose. Then place AC near an electrical outlet (fig.7). 5.3.7. Adjust the louvre at the air outlet, and then switch on the unit (fig.9). fig.6 fig.7 fig.8 SAC5000, SACWK1 Issue 1 29/11/24 Original Language Version © Jack Sealey Limited...
  • Page 5: Operation

    6.2.7.1. The TIMER has two ways of operation and can be activated by either the button on the control panel (fig.10 #7) or by the TIMER button on the remote control (fig.11). fig.11 SAC5000, SACWK1 Issue 1 29/11/24 Original Language Version © Jack Sealey Limited...
  • Page 6: Maintenance

    ‰ NOTE: Maintenance, service and repair must be carried out by qualified person. Contact your Sealey stockist for details. The removal of the plug has to be such that an operator can check from any of the points to which they have access that the plug remains removed.
  • Page 7: Troubleshooting

    Check for loose parts and re-tighten. Water flowing sound. Normal sound of refrigerant flowing. Error Communication faults between main PCB and Contact Sealey service centre. codes. display PCB. Ambient temperature sensor fail. Contact Sealey service centre. Coil temperate sensor failures.
  • Page 8 SAFETY To be used with Sealey SAC air conditioning units see sealey website for more details. DO NOT cover the unit with this material, and do not obstruct the air inlet and outlet grilles of the machine with items such as clothing,soft furnishings, furniture, bedding etc.
  • Page 9: Environment Protection

    BATTERY REMOVAL: REMOVE BATTERY FROM REMOTE Under the Waste Batteries and Accumulators Regulations 2009, Jack Sealey Ltd are required to inform potential purchasers of products containing batteries (as defined within these regulations), that they are registered with Valpak’s registered compliance scheme. Jack Sealey Ltd Batteries Producer Registration Number (BPRN) is BPRN00705.

This manual is also suitable for:

Sacwk1

Table of Contents