GRAUPNER ULTRA TRIO PLUS 14 Operating Manual page 42

Micro-processor controlled high-performance fast charger, discharger and battery conditioner for ni-cd / ni-mh, lipo / liio / limn / life and lead-acid batteries max. charge current 5 a, max. discharge current 1 a balancer function for li-batteries and ni
Hide thumbs Also See for ULTRA TRIO PLUS 14:
Table of Contents

Advertisement

Available languages

Available languages

L i P o
m a n u a l
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
2
sec.
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
L P - C 4 . 0 A
4 0 0 0 m A h
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
+
-
INC
DEC
ENTER
The charger automatically sets the charge current of 1C based on this information.
When you connect the pack to the charger and start the charge process, the charge current
starts at 0.00 A and slowly rises to the set limit.However, please do not be surprised if the
charger does not reach the current you have set, because the charge program constantly
monitors the battery voltage in order to prevent the pack inflating, provided that the voltage of
the individual cells in the pack is the same.When the charger automatically reduces the charge
current, the screen displays the message END, alternating with the reduced charge current.
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
L i P o
d i s c h a r g e
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
2
sec.
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
L P - D : 1 . 0 A
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
+
-
INC
DEC
ENTER
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
L i P o
s t o r e
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
2
sec.
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
< 2 . 0 A
3 . 8 0 V / C
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
+
-
INC
DEC
ENTER
42
Lithium manual program
This program charges the battery using the capacity
(charge current) which you set.
Before you initiate the actual program you must set the
charging current (range 0.1A...5.0A, left of the screen)
and the capacity of the pack (range 50...8000 mAh, right
on the screen) using the INC / DEC buttons. Switch
between the charge current and the capacity parameters
by using the ENTER button.
+
-
If the charged capacity reaches 110% of the adjusted
INC
DEC
capacity, the charging process is stopped for safety
reasons.
Lithium discharge program
The purpose of this program is to determine the residual
capacity of a Lithium pack which has not been fully
discharged.
The program discharges the pack using the set discharge
current (0.1 ... 1.0 A, left of screen) down to the set final
2 . 5 V / C
discharge voltage (2.5 ... 3.7 V per cell, right of screen). It
is not possible to set a final discharge voltage below 2.5 V
per cell, otherwise the battery will suffer permanent
+
-
damage.
INC
DEC
Lithium storage program
This program does charge or discharge the battery to the best
storage voltage.
The program does charge or discharge the battery to the
adjusted storage voltage, which is best for longer storage of
a Li-battery.
Best store voltage:
LiPo: 3,8...3,9V/cell
+
-
LiIo: 3,7...3,8V/cell
INC
DEC
LiFe: 3,3...3,4V/cell

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

6466

Table of Contents