Download Print this page
Whirlpool GI15NDXTB - 15" 50 lb. Icemaker Dimensional Information
Whirlpool GI15NDXTB - 15" 50 lb. Icemaker Dimensional Information

Whirlpool GI15NDXTB - 15" 50 lb. Icemaker Dimensional Information

Dimensions
Hide thumbs Also See for GI15NDXTB - 15" 50 lb. Icemaker:

Advertisement

®
PRODUCT MODEL NUMBERS
GI15NDXT
GI15NFLT
GI15NFRT
Electrical: 115 volt, 60 Hz, AC only, 15 or
20-amp grounded circuit is required. A time-delay
fuse or circuit breaker and separate circuit is
recommended.
Water: A cold water supply with water pressure
of between 30 and 120 psi (207 and 827 kPa) is
required.
Drain: Either a gravity-drain system or
condensate pump to carry water to an existing
drain.
CABINET OPENING DIMENSIONS
34"
(86.4 cm)
Min.
34 "
(87.6 cm)
Max.
(8.9 cm)
24"
(60.1 cm)
DRAIN REQUIREMENTS
REAR VIEW
REAR VIEW
A. Drain hose (drain pump models only)
B. Vent hose (drain pump models only)
C. Water supply line
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.

Ice Maker

11 "
(29.2 cm)
28 "
(72.4 cm)
9"
3
"
(22.9 cm)
15"
(38.1 cm)
SIDE VIEW
A
B
C
A. Drain hose
B. 1" (2.54 cm) air gap
C. PVC drain reducer
D. Center of drain should be 23" (58.4 cm) from front of door,
with or without the
drain should also be centered from left to right (7
[18.58 cm] from either side of the ice maker).
A. Recommended location for electrical
and plumbing fixtures.
B. Floor level
A
B
3⁵⁄₈"
(9.2 cm)
1" (2.54 cm)
23"
(58.4 cm)
2" - 1¹⁄₂"
(5 cm - 3.8 cm)
" (1.91 cm) panel on the door. The
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Drain lines must have a minimum of 5⁄8"
(15.88 mm) inside diameter.
Drain lines must have a 1" drop per 48" (2.54 cm
drop per 122 cm) of run or 1⁄4" drop per 12"
(6.35 mm per 30.48 cm) of run and must not
have low points where water can settle.
A
The floor drains must be large enough to
accommodate drainage from all drains.
B
The ideal installation has a standpipe with a 1-1⁄2"
(3.81 cm) to 2" (5.08 cm) PVC drain reducer
installed directly below the outlet of the drain tube
as shown. You must maintain a 1" (2.54 cm) air
C
gap between the drain hose and the standpipe.
D
It may be desirable to insulate the drain line
thoroughly up to the drain inlet.
"
Ref. 2313683
03-02-07