MOTOR SPECIFICATIONS
ELECTRICAL DATA
Volts
115
Hertz
60
RPM
3000
Watts
95
Amps
1.26
Therm. Prot.
Yes
MECHANICAL DATA
DESCRIPTION
Shaded Pole
Yes
Open
Yes
Int. Fan Cooled
Yes
CASING
Diameter (In)
3.33
Nom. Length (In)
4.50
SHAFT
Diameter (In)
.313
Nom. Length (In)
2.25
BEARINGS
Type
Sleeve
Material
Sintered Iron
COMPONENT DESCRIPTION
Relay (Model HSUL-J only)
24/115V Switching Relay
Timer Relay (Model HST-J only)
Dual Voltage 24/115V input, 1-10 minute post
purge adjustment
Fan Proving Switch (All Models)
3 FLA, 18LRA @ 120V
-SIDE VIEW-
P/N 8506001
REV. 1 11/94
TJERNLUND PRODUCTS, INC.
1601 Ninth Street • White Bear Lake, MN 55110-6794
PHONE (800) 255-4208 • (651) 426-2993 • FAX (651) 426-9547
Visit our web site • www.tjernlund.com
HSUL-J, HS115-J & HST-J POWER VENTER SPECIFICATIONS
Performance curves
Static pressure (inches H2O) vs CFM (std. air) at selected flue gas temps.
NOTE: TO ARRIVE AT TOTAL SYSTEM STATIC PRESSURE REFER TO CURVE
AND ADD .38" TO COMPENSATE FOR VENT HOOD AND WIND RESISTANCE.
-END VIEW-
MODELS AND APPLICATION:
HSUL-J (Gas)
Used as a means of Side Wall Venting 24 volt
controlled appliances. This Power Venter
includes a 24/115 volt switching Relay and a
Fan Proving Switch.
HS115-J (Gas)
Used as a means of Side Wall venting 115 volt
appliances. This Power Venter DOES NOT
include a Switching Relay but still includes the
Fan Proving Switch.
HST-J (Oil or Gas)
Used as a means of Side Wall Venting 24 volt
or 115 volt controlled appliances which require
a Post Purge cycle. This Power Venter
includes a Post Purge Timer Relay and a Fan
Proving Switch.
Note: Tjernlund Products, Inc. reserves the
right to make changes to specifications without
notification.
-PLAN VIEW-