How To Diagnose Trouble In Outdoor Unit - Toshiba Ras-B13B2Kvg-E1 Service Manual

Indoor unit, outdoor unit
Table of Contents

11-7. How to Diagnose Trouble in Outdoor Unit

11-7-1. Summarized Inner Diagnosis of Inverter Assembly
Diagnosis/Process flowchart
Remove connector
of compressor.
NG
Check 15A fuse
(Part No.F01).
OK
Replace fuse.
capacitor, diode
block (DB01),
Check
NG
terminal voltage
of electrolytic
capacitor.
OK
capacitor, diode
NO
Does outdoor
fan rotate?
YES
Remove connector
CN31 of outdoor fan
NG
motor, and using a
tester, check resistance
value between every
phases at motor side.
Replace
outdoor
fan motor.
A
Item
Preparation
Check
Check
Check
electrolytic
etc.
Check
electrolytic
(DB01),
etc.
Operation
Measurement
Check
OK
Stop
Check
Measurement
B
Table 11-7-1
Contents
Turn "OFF" the power supply
breaker, and remove 3P
connector which connects
inverter and compressor.
• Check whether 15A fuse
on the control board
assembly is blown or not.
(F01)
Turn on the power breaker,
and operate the air conditioner
in COOL mode by time
shortening.
Measure terminal voltage of
the electrolytic capacity.
500µF:400V
After operation, turn off the
power breaker after 2 minutes
20 seconds passed, and
discharge the electrolytic
capacitor by soldering iron.
Check voltage between motor
phases.
• Is not winding between
1 - 2 , 2 - 3 , or 1 - 3
opened or short-circuited
• Is not frame grounded with
1 , 2 , or 3 ?
- 86 -
Summary
If fuse was blown, be sure to
check the electrolytic
capacitor and diode block.
(DB01)
• Connect discharge
resistance (approx.
100Ω, 40W) or soldering
iron (plug) between +, –
terminals of the
electrolytic capacitor
(760µF) of C07
(with printed WARNING
ELECTRIC SHOCK) on
P.C. board.
Plug of
Discharging position
soldering iron
(Discharging period
10 seconds or more)
OK
if 500µF → DC290 to 400V
Remove CN31 while pushing
the part indicated by an arrow
because CN31 is a connector
with lock.
→ Resistance between phases
should be approx 34 ± 3.4Ω
→ Should be 100MΩ or more.
Table of Contents
loading
Need help?

Need help?

Do you have a question about the RAS-B13B2KVG-E1 and is the answer not in the manual?

This manual is also suitable for:

Ras-13b2avg-eRas-avg-e