Operation Data - Toshiba Ras-B13B2Kvg-E1 Service Manual

Indoor unit, outdoor unit
Table of Contents

7-2. Operation Data

<Cooling>
Temperature
Model name
condition(°C)
RAS-
Indoor
Outdoor
27/19
35/-
B13B2KVG-E1
<Heating>
Temperature
Model name
condition(°C)
RAS-
Indoor
Outdoor
20/-
7/6
B13B2KVG-E1
NOTES :
Measure surface temperature of heat exchanger pipe around center of heat exchanger path U bent.
(Thermistor thermometer)
Heat exchanger
Standard
pipe temp.
pressure
P (MPa)
T1 (°C)
T2 (°C)
1.0 to 1.1
9 to 11
48 to 49
Heat exchanger
Standard
pipe temp.
pressure
P (MPa)
T1 (°C)
T2 (°C)
2.4 to 2.5
40 to 42
- 22 -
Indoor
Outdoor
fan mode
fan mode
High
Indoor
Outdoor
fan mode
fan mode
1 to 2
High
Compressor
revolution
(rps)
High
72
Compressor
revolution
(rps)
High
80
Connecting
piping
(m)
5.0
Connecting
piping
(m)
5.0
Table of Contents
loading
Need help?

Need help?

Do you have a question about the RAS-B13B2KVG-E1 and is the answer not in the manual?

This manual is also suitable for:

Ras-13b2avg-eRas-avg-e

Table of Contents