Fluke 2063513 Instruction Sheet page 4

Multimeter with temperature
Table of Contents

Advertisement

W V Check
If a dc or ac voltage greater than about 4.5V is present across the inputs
when the meter is set to
to dc or ac voltage mode (V Check mode).
Repetitive transients on a dc bus will cause V Check to
select ac volts, even though a hazardous dc voltage may
be present. To avoid a misleading display and possible
electric shock, manually select the proper volts function
for measurements on these circuits.
When V Check is activated, the meter has low input impedance (LoZ)
2 k . This load can alter the voltages in electronic control circuits. Do
not use V Check to measure voltage in circuits that could be damaged by
a 2 k load.
Hint: V Check can be effectively used to eliminate "ghost" voltages.
16
MULTIMETER
OFF
V
Check
A
CAT
TEMPERATURE
600V
+
COM
or
R, G, or e
W
If AC detected
If DC detected
Meter puts
load on circuit.
, the meter switches automatically
Warning
Disable and re-enable V•Check
2 k
2 sec
or
or
For
,
Disables V•Check and
locks meter in selected
mode.
Re-enables
V•Check
and ,
ip09i.eps