Media-Card Reader; Redundant Array Of Independent Disks (Raid); Power Ratings - Dell Pro Max Slim Fcs1250 Owner's Manual

Table of Contents

Advertisement

● With a M.2 drive, the M.2 drive is the primary drive.
● Without a M.2 drive, the 3.5-inch hard drive is the primary drive.

Media-card reader

The following table provides the specification of media cards that are supported by your Dell Pro Max Slim FCS1250.
Table 15. Media-card reader specifications 
Description
Media-card slot type
Media-cards supported
NOTE:
The maximum capacity that is supported by the media-card reader varies depending on the standard of the media
card that is installed on your computer.

Redundant Array of Independent Disks (RAID)

For optimal performance when configuring drives as a RAID volume, Dell Technologies recommends using identical drive models.
NOTE:
RAID is not supported on Intel Optane configurations.
RAID 0 (Striped, Performance) volumes benefit from higher performance when drives are matched because the data is split
across multiple drives: However, any I/O operations with block sizes larger than the stripe size will be constrained by the
slowest drive in the array. For RAID 0 I/O operations where block sizes are smaller than the stripe size, whichever drive the I/O
operation targets, determines the performance, which increases variability and results in inconsistent latencies. This variability
is particularly pronounced for write operations, and it can be problematic for applications that are latency sensitive. One such
example of this is any application that performs thousands of random writes per second in very small block sizes.
RAID 1 (Mirrored, Data Protection) volumes benefit from higher performance when drives are matched because the data
is mirrored across multiple drives all I/O operations must be performed identically to both drives, thus variations in drive
performance when the models are different result in the I/O operations completing only as fast as the slowest drive. While this
does not suffer from the variable latency issue in small random I/O operations as with RAID 0 across heterogeneous drives, the
impact is nonetheless large because the higher performing drive becomes limited in all I/O types. One of the worst examples
of constrained performance here is when using unbuffered I/O. To ensure that that writes are fully committed to nonvolatile
regions of the RAID volume, unbuffered I/O bypasses cache (for example by using the Force Unit Access bit in the NVMe
protocol) and the I/O operation will not complete until all the drives in the RAID volume have completed the request to commit
the data. This kind of I/O operation completely negates any advantage of a higher performing drive in the volume.
Care must be taken to match not only the drive vendor, capacity, and class, but also the specific model. Drives from the same
vendor, with the same capacity, and even within the same class, can have different performance characteristics for certain
types of I/O operations. Thus, matching by model ensures that the RAID volume consists of a homogeneous array of drives that
deliver all the benefits of a RAID volume without incurring the additional penalties when one or more drives in the volume are
lower performing.
Dell Pro Max Slim FCS1250 supports RAID with more than one hard drive configuration.

Power ratings

The following table lists the power rating specifications of Dell Pro Max Slim FCS1250.
Table 16. Power ratings 
Description
Type
24
Specifications of Dell Pro Max Slim FCS1250
Values
One SD-card 4.0 slot (optional)
● Secure Digital (SD)
● Secure Digital High Capacity (SDHC)
● Secure Digital Extended Capacity (SDXC)
Option one
260 W, Bronze
Option two
360 W, Platinum

Hide quick links: