2-2. Operation Characteristic Curve

<Cooling>
12
10
8
6
4
2
0
0 10 20 30 40 50 60 70 80 90 100 110
Compressor Speed (RPS)

2-3. Capacity Variation ratio According to Temperature.

<Cooling>
105
100
95
90
85
80
75
70
65
60
55
50
45
40
35
Capacity ratio : 100 %=
30
7.00kW(RAS-B24G3KVSG(B)-E)
25
20
32
33
34
35
36
Outside Temperature (
Conditions
Indoor : DB 27
o
C/WB 19
o
C
Outdoor : DB 35
C/WB 24
C
o
o
Indoor Air Flow : High
Pipe Length : 7.5 m
Voltage : 230V/ 50Hz
Conditions
Indoor : DB 27
C/WB 19
o
Outdoor : DB 35
o
C/WB 24
Indoor Air Flow : High
Pipe Length : 7.5m
Voltage : 230V / 50Hz
37
38
39
40
41
42
43
o
C)
<Heating>
12
10
8
6
4
2
0
0 10 20 30 40 50 60 70 80 90 100 110
<Heating>
120
100
80
60
40
C
o
20
o
C
8.00kW(RAS-B24G3KVSG(B)-E)
Capacity ratio : 100 %=
0
44
45
46
-15
- 8 -
Conditions
Indoor : DB 20
Outdoor : DB 7
Indoor Air Flow : High
Pipe Length : 7.5 m
Voltage : 230V / 50Hz
Compressor Speed (RPS)
Conditions
Outdoor : DB 7
Indoor : DB 20
Pipe Length : 7.5m
Indoor Air Flow : High
Voltage : 230V / 50Hz
-10
-5
0
Outside Temperature ( ºC)
C/WB 15
C
o
o
o
C/WB 6
o
C
C/WB 6
o
C/WB 15
o
C
o
o
C
5
10

Advertisement