Dear Customer,
Thank you for deciding in favour of the oil water separator AQUAMAT. Please read the present instructions carefully
before installing your AQUAMAT unit and putting it into service. The perfect functioning of the Oil Water Separator
AQUAMAT - and thus reliable condensate treatment - can only be guaranteed if the recommendations and conditions
stated here are adhered to.
¡Estimado cliente!
Les agradecemes que se hayan a favor del separador de aceite/agua AQUAMAT. Sírvase leer las presentes
instrucciones antes del montaje y la puesta en marcha del AQUAMAT. Exclusivamente en caso de una observancia
concienzuda de las prescripciones y advertencias existentes, está garantizado el funcionamiento perfecto del
AQUAMAT y, de esta manera, un tratamiento del condensado fiable.
Cher client,
Vous venez d'acquérir un séparateur huile-eau AQUAMAT et nous vous en félicitons. Nous vous recommandons de
lire attentivement ces instructions avant le montage et la mise en service de l'AQUAMAT et de suivre nos conseils.
Car, seul le respect scrupuleux des prescriptions et consignes données peut garantir le parfait fonctionnement de
l'AQUAMAT et une séparation huile-eau fiable des condensats.
Exmo cliente,
Agradecemos que se decidiu pelo aparelho para separar óleo de água AQUAMAT. Faça o favor de ler com atençãoas
instruçoes antes de montar e pôr o AQUAMAT a funcionar. Só a cumprir as regras e conselhos dados garantem um
funcionamento correcto do AQUAMAT para o polishing de condensado.
AQUAMAT 2, 4, 5R
AQUAMAT 2
AQUAMAT 4
AQUAMAT 5R
english
español
français
português
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AQUAMAT 6 and is the answer not in the manual?

Questions and answers

Summarization of Contents

Important Rules
Safety Aspects
Key safety precautions and guidelines for installation and operation to prevent damage or injury.
Application Aspects
Defines suitable usage conditions, limitations, and types of condensate the AQUAMAT can process.
Operational Aspects
Guidelines for operating the AQUAMAT, including performance limits and filter usage.
Installation Guidelines and Best Practices
Continuous Slope Requirements
Ensures correct downward slope for condensation lines and feed hoses to prevent water pockets.
Leveling for Oil Escape
Details the importance of setting oil collectors at the same floor level for proper oil escape.
Installation Details and Connections
Area of Installation Requirements
Specifies requirements for the installation area, including flooring, stability, and inclination.
Inflow Connection Methods
Details how to connect multiple feed points, including the use of collecting lines.
Feed Line and Wastewater Drain Setup
Connecting the Feed Line
Guidance on connecting the feed adaptor, pressure relief chamber, and inlet hoses.
Wastewater Drain Setup
Details on positioning the wastewater drain lower than the outlet and installing a siphon.
Putting the AQUAMAT into Operation
Filling the Unit with Clean Water
Procedure for filling the AQUAMAT with clean water to prepare it for operation.
Checking the Oil Outlet
Instructions for verifying the oil outlet function and adjusting settings before operation.
Routine Maintenance and Checks
Weekly Wastewater Testing
Procedure for testing discharged water clarity to assess filter condition.
Oil Collector Maintenance
Guidance on checking oil collector levels and identifying issues like no oil discharge.
Level Indicator and Leak Checks
Procedures for checking the level indicator for blockages and inspecting for any leaks.
Filter Replacement Procedure
Filter Replacement Procedure Steps
Detailed steps for removing old filters, preparing new ones, and installing them correctly.
Collector Cleaning and General Maintenance
Dirt Collector Cleaning
Procedure for cleaning the dirt collector, recommended every six months.
Oil Outlet Verification
Steps to check for free oil passage and correct oil discharge, recommended every six months.
General Unit Cleaning
Guidelines for a comprehensive cleaning of the AQUAMAT unit, recommended annually.

Table of Contents