● If an INPUT channel is selected
Use the buttons in the lower part of the SAFE PARAME-
TER SELECT field (except for the "ALL" button) to
select the parameters that will be subject to Recall Safe
(multiple selections are allowed). If you want all parame-
ters to be subject to Recall Safe, turn on the ALL button
(this is the default setting).
These buttons correspond to the following parameters.
Button name
Corresponding parameters
ALL
All parameters
HA
Head amp settings (including external HA)
ATT
Attenuater settings
EQ
EQ settings (including HPF)
DYNA 1
Dynamics 1 settings
DYNA 2
Dynamics 2 settings
INPUT PATCH
Input channel patching
INSERT
Insert settings
INSERT PATCH
Insert patching
DIRECT OUT
Direct out settings
MIX SEND
Send levels of signals sent to MIX buses
MIX ON
On/off status of signals sent to MIX buses
MATRIX SEND
Send levels of signals sent to MATRIX buses
MATRIX ON
On/off status of signals sent to MATRIX buses
FADER
Fader positions
CH ON
On/off status of [ON] keys
NOTE
• If the ALL button is on, all other buttons in the lower part of the
SAFE PARAMETER SELECT field will be turned off.
● If a ST IN channel is selected
With the exception of the types of button that are dis-
played, this is the same as for an INPUT channel. These
buttons correspond to the following parameters.
Button name
Corresponding parameters
ALL
All parameters
ATT
Attenuator settings
EQ
EQ settings
DYNA 1
Dynamics 1 settings
DYNA 2
Dynamics 2 settings
INPUT PATCH
Input channel patching
MIX SEND
Send levels of signals sent to MIX buses
MIX ON
On/off status of signals sent to MIX buses
MATRIX SEND
Send levels of signals sent to MATRIX buses
MATRIX ON
On/off status of signals sent to MATRIX buses
FADER
Fader positions
CH ON
On/off status of [ON] keys
Using the Recall Safe function
NOTE
• If the ALL button is on, all other buttons in the lower part of the
SAFE PARAMETER SELECT field will be turned off.
● If a MIX channel is selected
Use the buttons in the lower part of the SAFE PARAME-
TER SELECT field (except for the "ALL" button) to
select the parameters that will be subject to Recall Safe
(multiple selections are allowed).
In addition, you can use the WITH MIX SEND button dis-
played in the lower-left part of the field to enable Recall
Safe for the on/off status and send level of the signals sent
from input channels to MIX buses.
If you want all parameters shown in the lower part of the
field to be subject to Recall Safe, turn on the ALL button
(this is the default setting).
These buttons correspond to the following parameters.
Button name
Corresponding parameters
ALL
All parameters (except for WITH MIX SEND)
ATT
Attenuator settings
EQ
EQ settings
DYNA 1
Dynamics 1 settings
INSERT
Insert settings
INSERT PATCH
Insert patching
MATRIX SEND
Send levels of signals sent to MATRIX buses
MATRIX ON
On/off status of signals sent to MATRIX buses
FADER
Fader positions
CH ON
On/off status of [ON] keys
OUTPUT PATCH
Output channel patching
On/off status and send level of signals sent from
WITH MIX SEND
input channels to MIX buses
NOTE
• If the ALL button is on, all buttons will be turned off except for the
WITH MIX SEND button located in the lower part of the SAFE
PARAMETER SELECT field.
• You can switch the WITH MIX SEND button on/off while the ALL
button is left on.