M INPUT [ASSIGN DCA] switch and LEDs
This switch assigns the input channel to DCA groups
1–12. When an input channel is assigned to a DCA
group, the corresponding LED will light. The LED
will blink while you are in the process of making
assignments to a DCA group.
Hint
It is possible to assign a single channel to multiple
DCA groups, as well as to assign multiple channels to
a single DCA group.
[Procedure]
Assigning an input channel to a DCA group
1. In the DCA GROUP block, press one of the
[ASSIGN DCA] switches 1–12 to select a DCA
group (1–12).
The LED of the selected [ASSIGN DCA] switch will
light.
If following step 1 you do not perform any action
for approximately ten seconds, the [ASSIGN DCA]
switch LED will automatically go dark, and the
assignment procedure will be terminated.
2. In the INPUT block, press the INPUT [DCA]
switch for the input channel that you wish to assign
to the above-selected DCA group.
While the DCA GROUP block [ASSIGN DCA]
switch LED is lit, all of the INPUT [DCA] LEDs
assigned to that DCA group will blink.
DCA faders 9–12 can be used for either input chan-
nels or output channels. However, it is not possible
to assign both inputs and outputs to the same DCA
fader. For this reason, if an output channel is already
assigned to DCA 9–12, attempting to assign an input
channel will cause a message to be displayed, and you
will not be able to do so.
When a scene is recalled, the DCA group data of
recall safe channels may be adjusted so that recall safe
settings are consistent within DCA groups 9–12.
Also when a channel library is recalled, the data
recalled to a channel may be adjusted so that settings
are consistent within DCA groups 9–12.
N SAFE [RCL] LED
This LED will light if the input channel has been set
to Recall Safe (a state in which the input channel is
unaffected by scene recall operations).
The parameters of a channel for which this LED is lit
will not change when a scene memory is recalled.
Recall Safe settings can be made in the SELECTED
INPUT CHANNEL block or display (SCENE func-
tion RECALL SAFE screen).
O SAFE [MUTE] LED
This LED will light if the input channel has been set
to Mute Safe (a state in which the input channel is
unaffected by mute group operations).
A channel for which this LED is lit will not be
affected even if a mute group to which it belongs is
muted.
Mute Safe settings can be made in the SELECTED
INPUT CHANNEL block or display (IN DCA/
MUTE function MUTE GROUP ASSIGN screen).
P [CUE] switch and LED
This switch is used for monitoring the input channel.
When this switch is pressed, the PFL (pre-fader lis-
ten), PRE PAN, or POST PAN signal of the corre-
sponding input channel will be sent to the CUE bus,
and can be monitored from the CUE OUT jacks,
MONITOR OUT A jacks, and PHONES jack.
The location of the signal that is sent to the CUE bus
and the monitoring method can be selected on the
console in the CUE section of the MASTER block, or
in the display (MON/CUE function CUE/SOLO
screen).
Hint
For the input channel signal flow, refer to the block
diagram on page 38.