JRC SAW FILTER
Application
Cordless telephone
Electrical Specification: (Table 1)
The device characteristics are measured in the circuit shown in Fig.1.
Table 1. Electrical Specifications
Item
Input and Output Impedance
Nominal Center Frequency (f0)
Insertion Loss
Response Variation
Input and Output VSWR
Out of Band Rejection
(Relative to
Through Level)
Maximum Rating: (Table 2)
Table 2. Maximum Ratings
Item
Maximum Input Power
Maximum DC Voltage
Operating Temperature Range
Storage Temperature
Mechanical Specifications: (Fig.2)
Package is designed as small as 3.5x3.5x1.0[mm
Notice:
This part is electrostatic discharge sensitive and may be damaged by improper handling.
Communications Equipment Marketing Department
http://www.jrc.co.jp/jp/product/device/saw/index.html (Japanese)
http://www.jrc.co.jp/eng/product/saw/index.html (English)
NSVA321
814~815MHz
814~815MHz
814~815MHz
DC~734.5MHz
734.5~772.9MHz
859.5~874.5MHz
874.5~1500MHz
Rating
+20dBm
7.5V
-10~+60ºC
-20~+70ºC
Communications and Device Group
10-1, Nishi-Shinjuku 6-chome, Shinjuku-ku,
Tokyo, 160-8328 Japan
Tel. +81 3-3348-3845
Fax. +81 3-3348-3935
Spec.
-
-
3.5dB max.
1.5dB max.
2.5 max.
55dB min.
45dB min.
30dB min.
55dB min.
(Operating Temperature Range: -10~+60ºC)
3
] for SMD (Surface Mount Device) type.
NSVA321 Oct. 2004
Typ.
50Ω
814.5MHz
3.0dB
1.0dB
2.0
65dB
55dB
40dB
65dB

Advertisement

   Summary of Contents for JRC NSVA321

  • Page 1

    NSVA321 Oct. 2004 JRC SAW FILTER NSVA321 Application Cordless telephone Electrical Specification: (Table 1) The device characteristics are measured in the circuit shown in Fig.1. Table 1. Electrical Specifications Item Spec. Typ. Input and Output Impedance 50Ω Nominal Center Frequency (f0) 814.5MHz...

  • Page 2

    NSVA321 Oct. 2004 50Ω 50Ω Fig.1 Measuring circuit 3.5±0.2 Marking (1) Manufacture’s Mark (2) Lot Number (a) Year (b) Month (0.95) (0.8) *Oct.--- X [5x] Nov.--- Y Dec.--- Z (3) Part number Mark (0.6) Pin no. Connection IN/OUT OUT/IN Fig.2 Package dimensions (in mm) [6x] Φ...

  • Page 3

    NSVA321 Oct. 2004 Notice 1. Use this component within operating temperature range. It might not be satisfied with electrical specification without operating temperature range. When it is used less than -10ºC or more than +60ºC, it might be a cause of degradation or destruction of the component.

  • Page 4

    NSVA321 Oct. 2004 ‚ ‚ ‚ 50 O *27nH ‚ U 39pF 50 O *27nH ‚ T ‚ ‚ ‚ ‚ 33pF FREQUENCY CHARACTERISTICS *murata LQW18A series Fig.1 Measuring circuit 13.30±0.20 (1.26±0.13) J4Y1 VS971 CH1 : center 814.5 span 200 CH2 : center 814.5 span 200...