Adjustment of Performance Monitor (NJU-63/64)・・・・・・・・・・・・・
Procedures
1
2
3
Open the ADJUST Menu as directed in
Section 8.5, Adjustments.
4
5
6
Set the radar to Master Radar when the Interswitch is
installed.
Press
to display VRM1 and set the range of VRM1 to
10-18* NM.
*
Set the range to 12 to 18 NM when a waveguide is installed between the
scanner unit and the transmitter-receiver unit. (X band radar)
*
Set the range to 12 to 18 NM when the transceiver unit is incorporated in
the scanner unit or in case of operating the S band radar.
Left-click on PM PRESET .
The PM PRESET Menu will appear. The radar
will automatically be set to RM, OFF CNTER
OFF, IR OFF, PROCESS OFF, TGT ENH OFF,
FUNCTION OFF and 24 NM range.
Affix the INFORMATION LABEL as
supplied with the Performance Monitor
to a suitable position of the board side
of the Display Unit.
Write down the value of the "PM"
indicator in the TEST Menu and the
date of checking in the INFORMATION
LABEL.
8-52
1.TUNE
0-63
   
2.BEARING
0.0-359.9°
3.RANGE
0-999
4.ANTENNA HEIGHT
5.
6.
7.
8.PM PRESET
0-127
0.
ADJUST
32
000.0
510
3.OVER 25m
ARPA
ISW
MBS
30
EXIT