Operation Of Performance Monitor; Operation Of Performance Monitor - JRC JMA-9922-6XA Instruction Manual

Marine radar equipment
Hide thumbs Also See for JMA-9922-6XA:
Table of Contents

Advertisement

● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Operation of Performance monitor・・・・・・・・・・・・・・・・・・・・・・・・・
This function con be used only when the radar equipment is equipped with the NJU-63/64
Performance Monitor.
1
Method of Operation
Procedures
Exit
In the case that the equipment is provided with radar interswitch, the interswitch
shall be set to the Master Radar mode.
1
Click TEST.
The MAIN Menu will appear.
2
Click "ON" radio button of
"5.PM".
"ON" in "5.PM" will be set and the radar will
automatically be set to RM, OFF CENTER
OFF, IR OFF, PROCESS OFF, TGT ENH
OFF, FUNCTION OFF and 24 NM range.
The PM pattern for checking the receiving
system will appear and the [PM] indicator
bar-graph will also be in the TEST Menu to
be used for checking the transmitted power.
1
Click EXIT .
The TEST Menu will be closed.
Note: All target acquisitions by ARPA functions will be cancelled.
The target acquisition cancelled when PM is ON will not be
recovered.
The radar image is suppressed to make the PM image easy to
see.
So, the test menu should be always closed after the PM has
been checked.
1.
2.
3.
4.MAG CURRENT
5.PM
6.
7.
PM
0.
3-89
TEST MENU
SELF CHECK
PANEL TEST
ARPATEST
OFF
ON
OFF
ON
ERROR LOGGING
SYSTEM INFO
EXIT