Technical Service - Desa Comfort Glow CGN12 Owner's Operation And Installation Manual

Desa vent-free natural gas heater owner's operation and installation manual cgn12
Table of Contents

Advertisement

TECHNICAL
SERVICE
20
If you smell gas
• Shut off gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call the
fire department.
OBSERVED
PROBLEM
Heater produces un-
wanted odors
Heater shuts off in use
(ODS operates)
Gas odor even when
control knob is in OFF
position
Gas odor during com-
bustion
You may have further questions about installation, operation, or troubleshooting.
If so, contact DESA International's Technical Service Department at 1-800-323-
5190.
!
WARNING
WARNING ICON
G 001
POSSIBLE
CAUSE
1. Heater burning vapors
from paint, hair spray,
glues, etc.
2. Gas leak. See Warn-
ing statement at
top of page
1. Not enough fresh air is
available
2. Low line pressure
3. ODS/pilot is partially
clogged
1. Gas leak. See Warn-
ing statement at
top of page
2. Control valve defective
1. Foreign matter between
control
valve
and
burner
2. Gas leak. See Warn-
ing statement at
top of page
REMEDY
1. Ventilate room. Stop us-
ing odor-causing prod-
ucts while heater is run-
ning
2. Locate and correct all
leaks (see CHECKING
GAS CONNECTIONS,
page 10)
1. Open window and/or
door for ventilation
2. Contact local natural gas
company
3. Clean ODS/pilot (see
CLEANING
AND
MAINTENANCE, page
17)
1. Locate and correct all
leaks (see CHECKING
GAS CONNECTIONS,
page 10)
2. Replace control valve
1. Take apart gas tubing
and remove foreign mat-
ter
2. Locate and correct all
leaks (see CHECKING
GAS CONNECTIONS,
page 10)

Advertisement

Table of Contents
loading

Table of Contents